This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.
...
Administrative Rights: Only system users with sufficient privileges can make changes to reader groups.
Supported Readers: All readers participating in the interlock function must be connected to the same door controller (on the same line).
Info |
---|
Since iProtect version 10.04 there is a multi-line solution, see chapter 7 |
Door Contacts: Each door in the reader group must be equipped with a magnetic door contact. This contact is essential, as it provides feedback on whether a door is open or closed. The system uses these contact statuses to determine the position
3. Steps to Create an Interlock Function Reader Group
...
Establish an additional output on Line 1 that activates whenever any door within Line 1's interlock group is opened.
Set the output source as Interlock reader group.
Set the correct Reader group (interlock) is specified as the source.
Physically connect this output to an input on Line 2. This setup enables Line 2 to detect when any door in Line 1’s interlock group is opened.
...