Go to the Reader Group menu under access | settings | reader group.
In the tree view, right-click and select Add Reader Group. Give the group a logical name, like “Interlock Group 1.”
Turn on the Interlock Function by checking Interlocking Reader Group. This ensures that only one door in the this group can be open at a time.
Info |
---|
The setting “operator must follow interlock rules” is off by default. If unchecked, an iProtect operator or API user can control doors in this group without interlock limitations. |
Step 2: Add Readers to the reader Group
Click on the + sign next to the newly created reader group to display the reader list.
Select the reader list in the tree-view; a detailed form will appear with a search box for the reader list.
Add the readers who should be included in the interlock group by checking the boxes next to the desired readers. Ensure that all selected readers are on the same controller.
Confirm your selections and save the changes.
...
With iProtect version 10.04, the interlock function can work across multiple lines, allowing doors on different lines to share an interlock group and block access when any interlock group door is open.
Info |
---|
To make sure the interlock function works in both directions, set it up the same way on each line, with each line having an output/input link and a virtual reader on the opposite line |
...
The following events that can be shown in the last event overview depend on the situation.
Event ID | Event name | Description | Is generated by |
---|---|---|---|
9. Frequently Asked Questions (FAQ)
...