  • Administrative rights: Only users with proper access rights can adjust reader groups.

  • Supported readers: All readers in the interlock group must be connected to the same controller (and be on the same line).

  • Door contacts: Each door in the reader group must have a magnetic door contact. This contact provides feedback to the system on whether a door is open or closed, which is needed for the interlock function to work.

  • Deadbolt contact (optional): When using a reader configuration with both a door contact and a deadbolt contact, both contacts should be idle (door closed and locked) for the interlock function to be inactive. If either contact becomes active, the interlock function is triggered. As a result, other doors in the group will blink and reject access until all contacts return to idle.

Info

Since iProtect version 10.04, the interlock function can be set up across multiple lines. See Chapter 7. Configuring the Interlock Function Across Multiple Lines for details.

...