4. Installation
4.1 Connecting the LPR camera to the Orion
The LPR camera is directly connected to the Orion Kp bus connector with the fixed cable from the camera, the maximum distance between the camera and the Orion is 15 mtr. The camera is powered by an external 24v power supply.
Cable color | Signal | ABC connector Orion KpBus (RS485) |
---|---|---|
Brown | + 24V | |
Grey | GND | |
Green | RS485 A | A |
White | RS485 B | B |
Yellow | RS GND | CC |
...