Installation Manual | TM-20230511

iProtect Access / Security | Functionalities |Voxio-A-3100-A reader

Image RemovedImage Added

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

...

4. Installation

4.1 Connecting the LPR camera to the Orion

The LPR camera is directly connected to the Orion Kp bus connector with the fixed cable from the camera, the maximum distance between the camera and the Orion is 15 mtr. The camera is powered by an external 24v power supply.

Cable color

Signal

ABC connector Orion KpBus (RS485)

Brown

+ 24V

Grey

GND

Green

RS485 A

A

White

RS485 B

B

Yellow

RS GND

CC

...