4.1 Connecting the reader

PHG connectorCable color

Signal

CAT5 cable > Orion PRT 1 or 2

Pin 1

Not in use

Pin 2

Not in use

Pin 3

B

White/Orange & White/Green

Pin 4

A

Orange&Green

Pin 5

Not in use

pin 6

GND

Brown

Pin 7

VCC 8-30V DC

Blue

ABC connector Orion KpBus (RS485)

Brown

+ 24V

Grey

GND

Green

RS485 A

A

White

RS485 B

B

Yellow

RS GND

CC

Info

Max. cable distance between Orion and the PHG LPR reader = 30 15 Mtr. This is based on CAT5E - 24AWG

Info

This cable distance is based without installing an The LPR reader must be connected to an 24V external power supply.

5. Implementation

...

Info

Most used setting for buzzer time = 2

5.4 Keypad buttons

...

Keypad

...

Description

...

0-9

...

Numeric numbers

...

C

...

On keypad is used as restore key to re-enter the PIN on the pending access request.

...

E

...

On keypad is used for reset pincode (do not use as pincode only key).

By reset pincode when using the pincode only function an reader error event occurs, with Error description: “Error: Wrong numbers of characters received”

The Voxio-A-3100-A reader can be used in three different access modes, depending on the authentication mode setting on the reader and the card data interpretation setting of the cards being used.

The reader authentication method can be set at the general tab on the reader detail page.

...

Mode

...

Reader authentication method

...

How to link

...

Card only

...

Not required

...

*Assign cards to people - Knowledge Base - Confluence (atlassian.net)

...

Card+Pincode

...

Pincode required

...

*Assign cards to people - Knowledge Base - Confluence (atlassian.net)

...

Card / Pincode only

...

Not required

...

6. Secure channel

OSDP v2 with Secure Channel has AES-128 encryption to ensure that communication between the targeted devices is strict and secure.

...