Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Installation Manual | TM-20230511

iProtect Access / Security | Functionalities |Voxio-A-3100-A reader

Image RemovedImage Added

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

...

Info

OSDP readers are only supported by stacked Orions (RS485 connection)

4. Installation

4.1 Connecting the LPR camera to the

...

Orion

Cable color

Signal

ABC connector Orion KpBus (RS485)

Brown

+ 24V

Grey

GND

Green

RS485 A

A

White

RS485 B

B

Yellow

RS GND

CC

...

  1. Connect the reader (see chapter “Connecting the reader”)

  2. Press the discover button in the line dialog of the Pluto.

  3. Wait until the discover process is ready: Read-in event=> Read-in event: Stop, Line: xxx…

  4. Refresh the line dialog of the Pluto, if an OSDP device is detected it will be shown as a Node below the Port of the Orion where the reader is connected to.

  5. Change the OSDP compatibility setting at the OSDP node to “No reader in capabilities”

  6. Right mouse click at the OSDP reader in the treeview and click on “add reader”

    • Fill in the logic unique name of the reader.

    • Click on the save button.

Info

If an rs485 reader has already been connected to the PRT port, the pluto must first be restarted before the discover is executed and the OSDP node can be created.

The discover function for OSDP devices checks for the following settings:
Baudrate:                    9600, 19K2, 115K2  baud,  They are all non-parity, 8 bit, 1 stop bit
Device address:          0, 1, 2, 3, 4, 5, 6, 7, 8, 13, 14, 24