This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.
Table of contents
Table of Contents |
---|
1. Introduction
This article explains how you can implement the Nedap target reader based on OSDP communication and describes the functions and settings.
...
2. Support and license
Below is an overview of support for both the hardware and the software, including the necessary license:
Version | License |
---|---|
Version 10.3.15 | iProtect basic license |
Sufficient reader licenses |
2.1 Supported cards
UHF DNA cards for specific project
Other cards or custom keys on request.
3. What is OSDP
Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.
...
Info |
---|
OSDP readers are only supported by stacked Orions (RS485 connection) |
4. Installation
4.1 Connecting the reader
Target Connector 5 | |
---|---|
Pin 3 | VCC 12-28V DC |
Pin 2 | GND |
...
Info |
---|
This cable distance is based with installing an external power supply. (for Reader and Sic) |
5. Implementation
5.1 General
OSDP readers are completely handled by the Nodemanager, so the Nodemanager should run to obtain access by a OSDP card reader.
The readermanager is not involved by handling the OSDP protocol
5.2 Configure the reader in iProtect
Follow the steps below to configure an OSDP reader:
...
Info |
---|
Nedap target defaults: 9600N81, OSDP address 0 |
5.3 OSDP reader settings
For OSDP readers there are some specific settings.
...
Info |
---|
Not supported by the nedap target reader. |
6. Secure channel
OSDP v2 with Secure Channel has AES-128 encryption to ensure that communication between the targeted devices is strict and secure.
...
Note |
---|
Once a key is set into the reader it cannot be cleared or rewritten by the system if the current key is not known. (not allowed in the OSDP protocol, security risk). If the key must be cleared (Reset) follow the procedure what is delivered by the reader manufacturer. |
7. General notes
By normal operation:
The red led ON, Idle situation
The red led is Blinking, Access denied
The green led is ON, Access granted
The led is purple when the connection is lost with the stacked Orion
8. iProtect settings
8.1 Card data presentation
Nedap target, with DNA tags:
Card data presentation | ||
---|---|---|
Format | Decimal | |
Calculated length | 9 |
8.2 Card data interpretation
Card data interpretation | ||
---|---|---|
Format | ||
Reader communication protocol | HEX | |
Card type | None | |
Data length | 28 | |
System code | ||
Start | 1 | |
Code | “empty“ | |
facility | ||
Start | 1 | |
Code | “empty“ | |
Card number | Start | 22 |
Length | 7 | |
Modulo | “empty“ | |
Offset | “empty“ |