Configuration Article | CA-20220907-TP-26

VDG Sense | API | Functions | Events

Image Added

PDF Download

Table of Contents

Note: This function requires an API license.

...

This signal is also stored in the database. It can be obtained with the command getEvents. Special care must be taken when including xml specific characters. These are ‘&’, ‘<' en '>‘. The ampersand (‘&’) character can not be sent by this command because it will be part of the URL. See next paragraph. The less-then (‘<') and greater-then ('>‘) character cannot be part of the return xml message in getEvents. These characters are converted to ‘<' and '>‘ before they are stored in the database.

...

This command is only available if the option XML is available.

Request

Code Block
command=genericEvent&value=[string]&serverid=[UID]&deviceid=[UID]

Response

parameter

type

remarks

value

[string]

The value used for the generic event.

serverid

[UID]

unique server id

deviceid

[UID]

unique device id.

error code

description

remarks

0

Ok

Ok, no error

-1

Not implemented.

Function not implemented.

-2

No device

 No device found for the supplied cameraid/deviceid.

-17

No server

There's no server with the supplied id.

-53

Device connection lost

Device has no connection.

Changelog

  • 2.2.1   – Handling of xml and html specific characters.

  • 1.12.1 – Added serverid and deviceid.

  • 1.11.1 – Added.