1 SimonsVoss and iProtect Aurora
...
Be sure that before the node will be configured in iProtect. The configuration of the SimonsVoss gateway
nodes and SimonsVoss handles/cylinder must be done by the SimonsVoss software. The result of this
configuration will be imported during the configuration of the SimonsVoss WO node into iProtect.
NOTE Please see the SimonsVoss WO manual how to configure handles and cylinders with the |
Click on configuration data at the SimonsVoss Smartintego Manager software at “file”> “export”.
Save the .csv file.
When using more than 1 Pluto the .csv file needs to be split into a separate import file per Pluto containing:
a. The Gateway nodes for a specific Pluto
b. The Lock nodes for a specific PlutoClick in iProtect at the menu item “installation” > “hardware” > “line”.
Click on the desired Pluto created at chapter 5.1.
Click on “upload” and select the saved .csv file.
Click on “import”.
When an AES encryption key is programmed in the SV gateway node the exact same key needs to be
entered at the “password” section of the node details in iProtect.
The import automatically generates programmed Gateway Nodes and Locks. Automatically the following
names will be generated:
...