Open a browser (Chrome, MS Egde or Firefox) and enter the url: https://ipaddressipaddressiprotect/apollo
...
Enter your credentials (username and password)
Press on the button “OK”
...
Enter a logical name of the template e.g., ApN-R1-default (ApolloN 1x RIO standard connection)
Select ApolloN
Select the number of RIO
Press on Save settings
...
You have the option to select some option which is appears in the site Floor plan.
Camera view (if you add camera’s in iProtect, you can display this in the floor plan)
Geo location (Open Street map loaded in your floor plan, client pc required internet connection)
Last events (live events of the pop location will be displayed in the floor plan)
Light control (Is not in used anymore)
Last Person (Picture of the person will be displayed in the floor plan, which enter the pop location)
Photo (You can upload a picture of the location, Png or jpeg)
Layout plan (You can upload a map of the pop location, all sensor icons will appear in this map)
...
If you have network device which are reachable with a browser, you can add some labels where you can create a hyper-link to the Ip address.
enter the name of the label e.g., UPS Webpage
Press on the button “New”
...
KPSENSOR Port (Temperature /Humidity)
Click on the KP sensor port
Enable this input
Enter the number of sensors (max 10)
If you want an alarm message in the alarm handler, enable this function
If you want a message by mail, enable this function. (Setup van mail server is required)
Click on save settings
...
Lock control port
Click on the lock control port
Enable the lock output which is related to the card reader (If you do not have a card reader, create an “Dummy” reader.
If you need some inputs, enable this function (e.g., door position, push button)
...
Reader port
...
Click on the reader port
Enable this port
If you have a motion detection, activate the Guarded area
...
A1 port
...
Click on port A1
Enable this port
Select e.g the PIR sensor
For this sensor you need to enable Guarded area
Click on the save settings button
...
A2 port
Click on port A2
Enable this port
Select e.g., the Smoke detector sensor
For this sensor you can enable the alarm handler and the email notification option.
...
A3 port
Click on port A3
Enable this port
Select e.g., the Shock sensor
For this sensor you can enable the alarm handler and the email notification option.
...
D1 port
...
Click on port D1
Enable this port
Select e.g the Water sensor
For this sensor you can enable the alarm handler and the email notification option.
Click on the save settings button
Threshold
...
Click on the icon “Threshold”
Click on the button “New”
Enter the limit values
Click on the save settings button
Template executions
...
Click on the icon Template executions
Click on the created template
Enter all required fields in
...
Example:
Enter a logical name for this ApolloN. (Remember this name appears every in the system)
Enter the ip address of the ApolloN
Enter the default reader group
Enter the location coordinates
Enter the label hyper-link
Select the threshold
Upload an picture of the location
Click on the button “save settings”
If you do’t get any errors, the ApolloN is add to your system
...