This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

Table of Contents

...

1. Introduction

This article explains how you can implement the voxio VOXIO-A-3100-A reader based on OSDP communication and describes the functions and settings.

...

2. Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Version

License

Version 10.3.15

iProtect basic license

Sufficient reader license

3. What is OSDP

Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.

...

Info

OSDP readers are only supported by stacked Orions (RS485 connection)

4. Installation

4.1 Connecting the reader

PHG connector

Signal

CAT5 cable > Orion PRT 1 or 2

Pin 1

Not in use

Pin 2

Not in use

Pin 3

B

White/Orange & White/Green

Pin 4

A

Orange&Green

Pin 5

Not in use

pin 6

GND

Brown

Pin 7

VCC 8-30V DC

Blue

...

Info

Max. cable distance between Orion and the PHG reader = 30 Mtr.

...

This is based on CAT5E -

...

24AWG

Info

This cable distance is based without installing an external power supply.

5. Implementation

5.1 General

OSDP readers are completely handled by the nodemanager, so the nodemanager should run to obtain access by a OSDP card reader.

The readermanager is not involved by handling the OSDP protocol

5.2 Configure the reader in iProtect

Follow the steps below to configure an OSDP reader:

  1. Connect the reader (see chapter “Connecting the reader”)

  2. Press the discover button in the line dialog of the Pluto.

  3. Wait until the discover process is ready: Read-in event=> Read-in event: Stop, Line: xxx…

  4. Refresh the line dialog of the Pluto, if an OSDP device is detected it will be shown as a Node below the Port of the Orion where the reader is connected to.

  5. Change the OSDP compatibility setting at the OSDP node to “No reader in capabilities”

  6. Right mouse click at the OSDP reader in the treeview and click on “add reader”

    • Fill in the logic unique name of the reader.

    • Click on the save button.

...

The discover function for OSDP devices checks for the following settings:
Baudrate                     9600Baudrate:                    9600, 19K2, 115K2  baud,  They are all non-parity, 8 bit, 1 stop bit
Device address          address:          0, 1, 2, 3, 4, 5, 6, 7, 8, 13, 14, 24

If other settings are necessary, set the these settings manually.

5.3 OSDP reader settings

For OSDP readers there are some specific settings.

It’s possible to setup the buzzer time when a card is recognized, this can be done at the door behavior tab of the reader.

Buzzer time , | card recognized:

Setting

behaviorBehavior

Empty

No buzzer when card is recognized

1 - 15

buzzer time (1/10 sec)

Info

Most used setting for buzzer time = 2

5.4 Keypad buttons

...

Keypad

Description

1-

...

9

Numeric numbers

C

On keypad is used as restore key to re-enter the PIN on the pending access request.

E

...

On keypad is used for reset pincode (do not use as pincode only key).

By reset pincode when using the pincode only function an reader error event occurs, with Error description: “Error: Wrong numbers of characters received”

6. Secure channel