Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Tip

PUBLIC

Installation Manual | TM-2023051120230629-AVW-01

iProtect Access / Security | Functionalities |Voxio-AT-31001570-A Z reader

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

Table of Contents

1. Introduction

This article explains how you can implement the VOXIOVoxio-AT-31001570-A Z reader based on OSDP communication and describes the functions and settings.

...

2. Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Version

License

Version 10.3.15

iProtect basic license

Sufficient reader license

2.1 Supported cards

  • TKH coded DESFire cards

  • Legic prime

Note

The card reader must be provided with key material to be able to read the desired cards.

3. What is OSDP

Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.

...

Info

OSDP readers are only supported by stacked Orions (RS485 connection)

4. Installation

4.1 Connecting the reader

PHG connector

Signal

CAT5 cable > Orion PRT 1 or 2

Pin 1Not in use

VCC 8-30V DC

Pin 2

Not in useGND

Pin 3

B

White/Orange & White/Green

Pin 4

A

Orange&Green

Pin 5

Not in use

pin 6

GND

Brown

Pin 7

VCC 8-30V DC

Blue

Info

Max. cable distance between Orion and the PHG reader = 30 Mtr. This is based on CAT5E - 24AWG

Info

This cable distance is based without installing an external power supply.

5. Implementation

5.1 General

OSDP readers are completely handled by the nodemanager, so the nodemanager should run to obtain access by a OSDP card reader.

The readermanager is not involved by handling the OSDP protocol

5.2 Configure the reader in iProtect

Follow the steps below to configure an OSDP reader:

...

The discover function for OSDP devices checks for the following settings:
Baudrate:                    9600, 19K2, 115K2  baud,  They are all non-parity, 8 bit, 1 stop bit
Device address:          0, 1, 2, 3, 4, 5, 6, 7, 8, 13, 14, 24

If other settings are necessary, set these settings manually.

5.3 OSDP reader settings

For OSDP readers there are some specific settings.

...

Info

Most used setting for buzzer time = 2

5.4 Keypad buttons

Keypad

Description

10-9

Numeric numbers

C

On keypad is used as restore key to re-enter the PIN on the pending access request.

E

On keypad is used for reset pincode (do not use as pincode only key).

By reset pincode when using the pincode only function an reader error event occurs, with Error description: “Error: Wrong numbers of characters received”

6. Secure channel

OSDP v2 with Secure Channel has AES-128 encryption to ensure that communication between the targeted devices is strict and secure.

...