Installation Manual | IM-20230628-AVW-02 iProtect Access / Security | Functionalities | iProtect™ - SimonsVoss VCN |
Table of Contents |
---|
1. iProtect Aurora and SimonsVoss VCN
...
At least the specified firmware versions are needed to let the system work properly.
Hardware | Description | Extra information | Versions |
iProtect | SMS | - | From: 9.03.02 Recommended from: 10.01.xx |
Pluto | Reader manager | - | From 5.00.41 Recommended from: 5.03.23 |
Hardware control applet | only needed when using iProtect version 9.10.xx and lower | From: 3.00 | |
Orion | Door controller | Bootloader | From: 2.3.0.15 Recommended from: 2.4.2.17 |
Firmware | From: 1.4.40 Recommended from: 1.5.18.86 | ||
Sirius | I Serie | - | From firmware: 1.5.32 |
Sirius | IX serie |
| From firmware: 2.0.5.a.1 |
SimonsVoss | SmartIntego VCN
| Use with iProtect version 09.03.02 and higher | 2.1.6411.25403 |
Use with Smartintego VCN version: 2.1.6411.25403 | Access DB Engine Runtime 2007 | ||
SmartIntego VCN
| Use with iProtect version 10.01.xx and higher | From 3.0.7600.18050 | |
SimonsVoss lock firmware | SV SI2 Cylinder | 5.4.16 | |
SV SI2 handle | 5.6.09 | ||
SV AX handle and Cylinder | 1.1.519 | ||
Card | Mifare DESFire | - | ev1 and ev2 |
2 Installing the SimonsVoss software
...
When using Smartintego VCN version 2.1.6411.25403 the standard TKH reader settings which must be set into the SimonsVoss Smartintego VCN software is as described below.
Column name: | TKH setting: |
ID | set as default |
Name | set as default |
AppId: | 16064888 (TKH security default) |
FileNo1: | 0 |
FileNo2: | 1 |
FileNo3 | 2 |
FileSize1 | 0016 |
FileSize2 | 1024 |
FileSize3 | 256 |
FileType1 | standard |
FileType2 | standard |
FileType3 | backup |
Please contact your consultant or the TKH service and support department for the “TKH_security_defaultSVVCN_cardconfig_DES.ikt” template file or the KEY information.
...
Click in iProtect™ Aurora on the menu item Access | settings | card coding | card data number presentation
Right-click in the browse window and press on “Wizard card number presentation”
...
The following transactions and events will be stored on the card:
Amount | Type | Description |
10 | Access transaction | Regular access transaction |
2 | Access denied transaction | Regular access denied transaction with reason why the access is denied. |
10 | Prio events | Event forlock information and battery statuses. |
10 | Status events | Event with status information for e.g. hotlist and other operations |
Transactions are stored on the card with an offset timestamp from the expiration date, this offset has a maximum of 21 days. So, when the validity period is set to long the offline transactions will have an incorrect timestamp. We advise a maximum validity period of 24:00.
...
To monitor the technical status of a lock, an analogue input is automatically created for the lock battery status. The battery status is updated to the iProtect system by the access cards using the update reader(s)
Battery status:
Input name | Available levels |
Battery status | OK |
Replace battery (30 days left) | |
Alarm (20 days left) | |
No status available |
6.3 Online reader features
...
Error feedback from the reader:
Feedback | Meaning |
LED blinks GREEN/RED | Card has no valid access profile on the enrollment reader |
Beeps twice | Error beep. Card update fails |
Please notice that during an error, a transaction is created in iProtect. This transaction contains more detailed information.
...
Error feedback from the reader:
Feedback | Meaning |
LED blinks GREEN/RED | Card has no valid access profile on the update reader |
Beeps twice | Error beep. Card update fails |
Please notice that during an error, a transaction is created in iProtect. This transaction contains more detailed information.
...