Installation manual IPR-IX10-xxx
| |
This document contains the information needed for installing the Sirius iX10. Details and recommendations are described in the chapters below. This manual represents the knowledge at the above-mentioned date. TKH security works non-stop to improve the products. For the most recent technical information please contact your consultant or dealer.
...
T-568B, or another cable which meets the requirements as specified in Maximum cable lengths.
This document assumes standard T-568-B color coding of the cables.Wire side cutter
Electric wire ferrule
Crimping tool
Philips screwdriver
...
The Sirius iX10 card reader is suitable for indoor use in an enclosure.
For proper operation, the reader must be installed behind a panel of 9mm (plexi) glass.
The IP rating of the Sirius iX10 card reader depends on the enclosure in which the iX reader is placed.
The Sirius iX10 operates between a temperature of -40°C and + 85°C.
Determine the location where the Sirius iX10 card reader should be installed. Please note that there is a maximum cable length between the card reader and the door controller (Maximum cable lengths).
The connection and cable length of the Sirius iX10 depends on the chosen data output.The Sirius iX10 should not be installed directly on metal.
The reader is intended as a built-in module. Put the reader as close to the front plate as possible, everything placed in front of the reader decreases the RFID (radio frequency identification) range.
The Sirius iX10 should not be mounted higher than two meters.
Keep a minimum distance of 20 cm between Sirius iX10 card readers *1.
...