Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

Table of content

Table of Contents

1. Introduction

This article explains how you can implement the Simons Voss SI pincode reader based on Wireless online communication and describes the functions and settings.

...

The access management of the PIN code cards takes place entirely in iProtect.

image-20240307-125220.png

2. Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Software Name

Version

License

iProtect

10.04.x

iProtect basic license

  • SV WO license

  • Online Reader license

SmartIntego Tool Application

3.1.7760.17076

3. Implementation

3.1 Configure the pincode length in the pincode reader.

The implementation of the keypad reader takes place in several areas. First you must determine how many characters the PIN code should contain.

...

Info

For the authentication method, iProtect supports a 4 or 6 digit PIN code.

3.2 Add the pincode reader to the SmartIntego configuration.

If the pincode length configuration is in the keypad reader, you must add the keypad reader to the SimonsVoss gateway node, which you must do in the SmartIntego tool from SimonsVoss

...

Note

If the entire configuration is spread over multiple plutos, you must adjust the xml so that there is one configuration file per pluto.

3.3 Add the pincode reader to the iProtect configuration.

In iProtect go to Installation > hardware >line in the menu structure.

...

On the detail page of the keypad reader, you can change the name of the reader and select the desired online reader which should be controlled by the keypad reader.

3.3.1 fields descriptions.

Label

Description

Name

Logical name of the keypad reader

Nodeid

SimonsVoss gateway node where the keypad reader is linked to.

Readerid

SimonsVoss Reader which receives the pressed key from the keypad.

Type

Keypad type

Communication status

Last reported communication status

Version

Firmware version of the keypad

Local address

Local address of this Keypad

Below the keypad reader in the tree structure there are two keypad sensors that can be monitored. these are the battery sensor and the signal strength sensor.

4. Card configuration and usage.

4.1 Alternative access by using a pincode.

To gain access with the keypad reader as alternative access to an SV wireless online reader, a separate card configuration must be created in iProtect for the PIN code cards. also, a leading number (Pincode only start key) must be set in the existing card configuration, which is set on the corresponding SV reader controlled by the keypad reader. You can use the manual below to set this up.

...

Once the PIN only card has been created, you can gain access to the linked reader by first entering the leading number on the keypad reader, followed by the card number.

4.1 Use the keypad as additional authentication.

To enable extra authentication, you must set this on the linked reader on which the card is presented.

...

Once this has been set, after presenting the card, you must enter your personal 4 or 6-digit pincode on the keypad reader to gain access.

5. Events

Event ID

Event name

Description

4

Subscriber card no access {Error} Authentication timeout

The reader did not receive the Pincode {in time}.

125

User presented unknown rcn card

The typed Pincode card for the alternative access is not in the systems database.

200

Authentication failed

The additional authentication on the keypad reader was incorrect. {pincode did not match with the card}

201

Authentication successful

The additional authentication on the keypad reader was correct.

...