  • Explosion-protected, Atex and IECEx Zone 1, for use in onshore, offshore, marine, and heavy industrial applications

  • ¼” 36x Analogue zoom moduleWall or pole mount options

  • Electro-polished 316L stainless steel construction

  • Standard wiper and optional washer tank

  • Integral multi-protocol telemetry receiver

  • Optional integrated digital video over fiber transmitter

Order information

EX-BC36/P F 24 3C

Ex 316L fixed analogue, 36x PAL 24Vac 3m conduit 20 mm M20

EX-BC36/P F 24 2SM 3C

Ex 316L fixed analogue, 36x PAL 24Vac, 2SM 3m conduit 20 mm M20

EX-BC36/P F-WW 24 3C

Ex 316L fixed wiper analogue, 36x PAL 24Vac 3m conduit 20 mm M20

EX-BC36/P F-WW 24 2SM 3C

Ex 316L fixed wiper analogue, 36x PAL 24Vac, 2SM 3m conduit 20 mm M20

EX-BC36/N F 24 3C

Ex 316L fixed analogue, 36x NTSC 24Vac 3m conduit 20 mm M20

EX-BC36/N F 24 2SM 3C

Ex 316L fixed analogue, 36x NTSC 24Vac, 2SM 3m conduit 20 mm M20

EX-BC36/N F-WW 24 3C

Ex 316L fixed wiper analogue, 36x NTSC 24Vac 3m conduit 20 mm M20

EX-BC36/N F-WW 24 2SM 3C

Ex 316L fixed wiper analogue, 36x NTSC 24Vac, 2SM 3m conduit 20mm M20

For 115 Vac or 230 Vac option

Replace 24 with 115 or 230 respectively

For 5 or 10 meter conduit

Replace 3C with 5C or 10C respectively

Camera housing

Certification

ATEX, IECEx

...

II

...

2

...

G

...

Ex

...

d

...

op

...

pr

...

IIC

...

T6

...

II

...

2

...

D

...

Ex

...

tb

...

IIIC

...

T85°C

...

Db

...

IP66/67

Ingress protection rating

IP66/ IP67

Body material

Electro-polished 316L stainless steel

Conduit

20 mm low fire hazard, liquid tight conduit Galvanised steel core.Zero halogen

Glands

2x M20 Brass flameproof barrier glands, pre-assembled

Length

3 meter. Optional 5 or 10 m

Sunshield

Standard

Internal demister/heater

Standard

Wiper

Optional (F-WW version only)

Washer system

Optional (EX-WP10 Ex e 24 or EX-WP10 Ex d 24)

Operating temperature

-20 °C to +60 °C

“Dry heat” test

+75 °C, 2 days

Weight EX-BC36 F 24 3C

12 kg

Weight EX-BC36 F-WW 24 3C

14 kg

Electrical

Zoom, wiper and washer control

2-wire RS485, Pelco D, 2400 baud

Supply voltage

24 V 50/60 Hz; Optional 115 V 50/60 Hz; 230 V 50/60 Hz

Power consumption

95 W maximum

Electrical connections

3 wire power cable from the conduit, 0.75 mm2

Camera

Image sensor

1/4” Ex-View HAD CCD

Effective pixels

380,000 (NTSC) or 440,000 (PAL)

Shutter speed

1/3 - 1/10000 s

Minimum scene illumination

0.1 lux (colour), 0.01 lux (b/w), F/1.6

Dynamic range (WDR)

90 dB

Lens

36x Optical zoom, F/1.6 (W), F5 (T); 12x digital zoom

Lens focal length

3.4 mm (W) – 122.4 mm (T)

Horizontal field of view

57.8° (W) – 1.7° (T)

Features

WDR, (3D/2D) noise,

Exposure

Auto (iris)

Day/Night (IR-cut filter)

Auto

Video

Component Video

/P version for PAL /N version for NTSC

Resolutions

550 TVL

Video frame rate

/P version: 25 fps /N version: 30 fps

Video output

RG179 75 Ω coax from the conduit

Accessories

EX pole mounting adapter F

316L pole mounting adapter for EX wall mounting bracket F

EX wall mounting bracket F

316L wall mounting bracket for EX fixed camera housings

EX Pole Top Mounting F

316L Pole TOP Mounting bracket for EX fixed camera housing

EX-WP10 Ex d 24 (EX-WP10 Ex e 24)

10 liters pressurized washer tank, 316L cabinet, Ex d (or Ex e) solenoid

Ex e termination box IP (Ex e termination box fiber)

316L Ex e termination box for IP camera (316L Ex e termination box for fiber cameras)

Maintenance & replacement kits

EX/SA-MK Wiper

Maintenance kit for the wiper: Rubber blade and support

EX/SA-Wiper

Replacement for Stainless steel wiper (complete assembly)

EX-MK fixed

Maintenance kit EX fixed camera: O-Ring, screws, desiccant bags