  • ATEX and IECEx certified for gas and dust

  • Single integrated flexible conduit tail

  • Corrosion protected 316L stainless steel

  • 640x512 LWIR thermal camera with built-in

    • Hot spot or fire detection

    • Flare too small / too large detection

    • Custom colour palettes

  • Complete range of thermal lenses available

  • Integrated heater

  • Direct to Fiber (optional)

  • ONVIF profile S compliant

...

Camera housing

Certification

ATEX, IECEx

...

II

...

2

...

G

...

Ex

...

d

...

op

...

pr

...

IIC

...

T6

...

II

...

2

...

D

...

Ex

...

tb

...

IIIC

...

T85°C

...

Db

...

IP66/67

Ingress protection rating

IP66/ IP67

Body material

Electro-polished 316L stainless steel

Conduit

20 mm low fire hazard, liquid tight conduit Galvanised steel core zero halogen

Glands

2x M20 Brass flameproof barrier glands, pre-assembled

Length

3 m; Optional 5 or 10 m

Sunshield

Standard

Internal demister/heater

Standard

Wiper

N/A

Operating temperature

-20 °C to +60 °C

“Dry heat” test

+75 °C, 2 days

Weight

12 kg

Electrical

Supply voltage

24 V 50/60 Hz; Optional 115 V 50/60 Hz; 230 V 50/60 Hz

Power consumption

25 W maximum

Electrical connections

3 wire power cable from the conduit, 0.75 mm2

Thermal imager

Imager

Uncooled micro-bolometer

Pixel pitch

17 µm

Resolution

336 x 256 pixels

Focal length

7.5 mm | 9 mm | 13 mm | 19 mm | 25 mm | 35 mm | 50 mm

Field of view

45°x35° | 35°x27° | 25°x19° | 17°x13° | 13°x10° | 9.3°x7.1° | 6.5°x5°

f-number

f/1.4 | f/1.25 | f/1.25 | f/1.25 | f/1.1 | f/1.5 | f/1.2

Spectral bandwidth

7.5 µm to 13.5 µm (LWIR)

Frame rate

8.3 fps (xx-S version) Optional: 30 fps (xx-F version)

Sensitivity (NEdT)

< 50 mK @ f/1.0

Time to image

Instantaneous

Digital zoom

No

Analytics

Freeform zones or detection lines

2x in stand-alone (Web configured) up to 8x with the “VCA Configuration Server”

Event type

Detection line: Touch, Cross (directional sensitive), Cross

...

Detection

...

zone:

...

Touch,

...

Enter,

...

Inside,

...

Exit

Event time

0 to 10 s

Event output

generic ONVIF, digital I/O, SPI

Measuring range

-40 °C to 550°C

Accuracy

+/- 20 °C (T< 100 °C) or +/- 20% (T> 100 °C)

Video

Number of video streams

2x H.264/MJPEG

Max resolution

720 x 512 @ 25/30fps (upsampled)

Number of output streams

Up to 20 (RTSP)

Compression algorithm(s)

H.264 (H.264/MPEG-4 AVC), MJPEG

Encoder bit rate control

Constant bit rate (CBR), variable bit rate (VBR)

Output bit rate (per H.264 stream)

Up to 6 Mbit/s

Total output data rate

Up to 32 Mbit/s

Video overlay

3x Text, 1x bitmap (BMP, GIF); PID Object data (blue blob), event data (red box);

Network

Interface(s)

10/100 Mb Ethernet (4-wires 0.5 mm2 from conduit)

Protocols

IPv4, TCP/IP, UDP, RTP, RTSP, HTTP, HTTPS, ICMP, FTP, SMTP, DHCP, , UPnP, IGMP, SNMP, QoS, ONVIF

Password levels

User and Administrator

Supported browsers

Internet Explorer (6.0+), Chrome, Firefox, Safari

User accounts

20

Accessories

EX pole mounting adapter F

316L pole mounting adapter for EX wall mounting bracket F

EX wall mounting bracket F

316L wall mounting bracket for EX fixed camera housings

EX Pole Top Mounting F

316L Pole TOP Mounting bracket for EX fixed camera housing

Ex e termination box IP

316L Ex e termination box for IP camera

(Ex e termination box fiber)

(316L Ex e termination box for fiber cameras)

Maintenance & replacement kits

EX-MK F

Maintenance kit EX Fixed camera: O-Ring, screws, desiccant bags

Please Note: Thermal cameras fall under export restrictions. Please, contact Siqura for more information.