*Devices – I/O

Configuration Article | CA-20200930-TP-06

VDG Sense | Setup | Devices | I/O

Add or Edit an I/O Device
To add an I/O Device click on the ’+’-button. At tab General give the device a name, choose a location, choose the type and set the IP-address. To edit a device click on the device row. The name of the device is used to give operators a human readable identifier. A name which descibes the function is well understood by most people. The purpose of locations is to group devices which are on the same physical location. This to prevent long device list when there are a lot of devices. Choose an existing location or type in a new location. New locations are automatically added to the list.

The following Advantech Adam I/O devices are supported:

  • ADAM-6050
    The ADAM-6050 is a high-density I/O module built-in a 10/100 based-T interface for seamless Ethernet connectivity. It provides 12 digital input and 6 digital output channels with 2000VRMS isolating protection.

  • ADAM-6051
    The ADAM-6051 provides 12 digital inputs, 2 digital outputs, and 2 counters with 2000VRMS isolation protection. This mixed-function module built-in Ethernet port and web page.

  • ADAM-6052
    16-channel Source Type Digital I/O Module, 8 inputs and 8 outputs.

  • ADAM-6060
    Built in an Ethernet port and web page, the ADAM-6060 offers 6 relay (form A) output and 6 digital input channels. It supports contact rating as AC 120V @ 0.5A, and DC 30V @ 1A.