*Event types

How To Article | HTA-20201001-TP-03

VDG Sense | Operator | Events

Event name 

 Event value

Description

Remarks

Licensed

Event name 

 Event value

Description

Remarks

Licensed

Alarm Input 1

n/a

this event is generated when physical input 1 on a camera is triggered

if supported by VDG Sense for this camera

no

Alarm Input 2

n/a

this event is generated when physical input 2 on a camera is triggered

if supported by VDG Sense for this camera

no

Alarm Input 3

n/a

this event is generated when physical input 3 on a camera is triggered

if supported by VDG Sense for this camera

no

Alarm Input 4

n/a

this event is generated when physical input 4 on a camera is triggered

if supported by VDG Sense for this camera

no

AlarmInputHigh

 D0-D11

this event is generated when physical input Dx is triggered on a ADAM IO module  

range depending on ADAM type

no

AlarmInputLow

D0-D11

 this event is generated when physical input Dx is reset on a ADAM IO module  

range depending on ADAM type

no

CamAlarmInputHigh

Alarm number

this event is generated when physical input x on a camera is triggered

if supported by VDG Sense for this camera

no

CamAlarmInputLow

Alarm number

this event is generated when physical input x on a camera is reset 

if supported by VDG Sense for this camera

no

Connection Lost

n/a

this event is generated if the connection to the camera is lost

 if the camera is not receiving video for more than 5 seconds this event is generated

no

Reconnect

n/a

this event is generated if the camera connection is restored

 

 no

Video Lost

n/a

this event is generated if an analog camera is disconnected from an encoder

if supported by VDG Sense for this camera

 no

Video Restored

n/a

 this event is generated if an analog camera re-connected to an encoder

if supported by VDG Sense for this camera

 no

Motion

Percentage of motion 1% – 100%

this event is generated if the amount of motion is equal or more than 1%

if enabled in 'Profiles' menu or 'Device Motion detection' is enabled

 no

ObjectRRule1

custom event text

this event is generated if rule 1 of the by the ObjectR Basic algorithm is triggered

if enabled in 'ObjectR General' menu 

yes

ObjectRRule2

custom event text

this event is generated if rule 2 of the by the ObjectR Basic algorithm is triggered

if enabled in 'ObjectR General' menu

yes

ObjectRRule3

custom event text

this event is generated if rule 3 of the by the ObjectR Basic algorithm is triggered

if enabled in 'ObjectR General' menu

yes

ObjectRRule4

custom event text

this event is generated if rule 4 of the by the ObjectR Basic algorithm is triggered

if enabled in 'ObjectR General' menu

yes

ObjectRRule5

custom event text

this event is generated if rule 5 of the by the ObjectR Basic algorithm is triggered

if enabled in 'ObjectR General' menu

yes

Siqura VCA

line x: custom text or zone x: custom text

this event is generated if line 1-8 or zone 1-8 of the ObjectR Advanced algorithm is triggered 

if enabled in 'Advanced' menu of the camera  

yes

Observision Event

custom text

this event is generated if by the Observision or VSC server 

if enabled in ObjectR general tab in ObjectR advanced treeview menu

yes

SceneR Camera Angle Change

n/a

this event is generated if the SceneR algorithm detected a camera angle (field of view) change  

 if enabled in 'Profiles' menu

 no

SceneR Scene Loss

n/a

this event is generated if the SceneR algorithm detected if the camera picture is obscured 

 if enabled in 'Profiles' menu 

 no

SceneR CameraAngle Change Ref

n/a

this event is generated if the SceneR algorithm detecteda camera angle (field of view) change based on the reference image

 if enabled in 'Profiles' menu 

 no

SceneR Scene Loss Ref

n/a

 this event is generated if the SceneR algorithm detected if the camera picture is obscured based on the reference image

 if enabled in 'Profiles' menu 

 no

FaceRMatch

confidence 0% – 100% , Person name

this event is generated if a face is recognized based on a person in the 'Database'

 if enabled in 'Profiles' menu, only availale for FaceR algorithm 

 yes

FaceRFaceFound

confidence 0% – 100%

this event is generated if a face has been detected

if enabled in 'Profiles' menu, available for both FaceR and FaceD

FaceD not, FaceR yes

CarR License Plate Found

License plate, country, confidence (0 – 100%)

this event is generated if a license plate has been detected

 if enabled in 'Profiles' menu

yes

CarR Match

Person name

this event is generated if a license plate has been recognized based on a person in the 'Database' 

 if enabled in 'Profiles' menu

yes

POSNozzleOut

Pump number

this event is generated if a nozzle is taken out of the nozzle-socket (fuel station)

if enabled in 'POS' menu

yes

POSNozzleIn

Pump number

this event is generated if a nozzle is put back in the nozzle-socket (fuel station)

if enabled in 'POS' menu

yes

POSFillingStarted

Pump number

this event is generated if filling has started (fuel station)

if enabled in 'POS' menu

yes

DivaNotClosedGracefully

n/a

this event is generated if the last shutdown of the server server is not done gracefully

generated on when server is started

no

NoRecording

Timestamp of last recorded image

 this event is generated if one of the camera has not recorded an image for more than 24 hours

 

no

ServerConnectionLost

n/a

this event is generated when a client loses connection to a server

this event is not stored in the database

no

ServerConnectionRestored

n/a

this event is generated when a client restored the connection to a server

this event is not stored in the database

no

GenericEvent

custom text

this event is generated via a macro or via the API

 

no

UserLoggedInEvent

n/a

this event is generated if a user logs in

 

no

TraficonEvent

n/a

this event is generated by the Traficon plugin for a specific device

configuration is done in FLUX server by Flir

yes

SystemFailover

n/a

this event is generated by the Failover server if a monitored server has failed

 

yes

SystemRestore

n/a

this event is generated by the Failover server if a monitored server has been restored 

 

yes

ClientConnectionLost

client name

this event is geneated by the management server if it detects if a client has lost the connection to the management server

configuration done via ClientWatchdogPlugin

no

ClientConnectionRestored

client name

this event is geneated by the management server if it detects if a client has restored the connection to the management server

configuration done via ClientWatchdogPlugin

no

Related pages