*Default LED behavior and LED Color
Specification Article | SA-20210309-TP-06 Access Control | Readers | Sirius Card Readers | |
COLOUR
In addition, the standard colors are described.
DESCRIPTION | COLOUR | BEHAVIOR | REPEAT COUNT |
---|---|---|---|
POWER ON | RED |
|
|
ACCESS * | GREEN |
|
|
NO ACCESS * | GREEN | BLINKING | 6 |
UPDATE (PROVISIONER) | BLUE |
|
|
CONFIG MODE (STAND-ALONE) | BLUE |
|
|
CONFIG CARD | LIGHT BLUE |
|
|
BLE CONNECTING | YELLOW |
|
|
INSTALLER CARD MADA | YELLOW | FADING | 30 seconds |
INSTALLER CARD ENABLE BLE | YELLOW | BLINKING | 3 |
PROGRAMMING | BLUE | BLINKING |
|
* See table below (LED STATE) to get the full explaination of the LED behavior
LED STATE
This page describes the default LED behavior for a certain state.
LED COMMAND | OFF-TIME (msec) | ON-TIME (msec) | REPEAT COUNT |
---|---|---|---|
NONE | 0 | 0 | Till none stops |
WALK ROUTE | 800 | 400 | Till walk route stops |
BLOCKED | 700 | 700 | One time only |
ARMED | 400 | 400 | Till armed stops |
CONFIRM | 100 | 100 | Till confirm mode stops |
READER ERROR | 200 | 200 | 6 |
NO ACCESS | 300 | 300 | 6 |
WAITING / PENDING | 500 | 500 | Till waiting / pending stops |
PINCODE REQUEST | 400 | 400 | Max 15000 ms, or shorter when the pincode is filled in |
ACCESS | Door unlatch time is definable in iProtect | As long as the door unlatch time | |
LATCH / OFFICE MODE | 0 | 100 | Till latch / office mode stops |
EMERGENCY DOOR RELEASE | 1 | 1 | Till emergency stops |
ALARM | 200 | 200 | Till alarm stops |
PROGRAMMING | 100 | 100 | Till programming ends |
DISARM FAILED | 200 | 200 | Till disarm failed ends |