The NVITE reader can be used with multiple identification technologies for variety of users, such as staff, tenants and visitors. Identification is depending on the userenabled technologies: presenting a card, scanning a barcode or activating a smartphone credential. Typical applications are access control to car parks, perimeter gates, office buildings and warehouses.

2. Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Version

License

Version

License

Version 10.3.15

iProtect basic license

 

Sufficient reader license

2.1 Supported cards

  • TKH coded DESFire cards

  • QR code

The card reader must be provided with key material to be able to read the desired cards.

Other cards or custom keys on request.

3. What is OSDP

Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.

OSDP was approved as an international standard by the International Electrotechnical Commission in May 2020 and has been published as IEC 60839-11-5.

OSDP V2.2 which is based on the IEC 60839-11-5 standard, was released in December 2020.

OSDP readers are only supported by stacked Orions (RS485 connection)

4. Installation

4.1 Connecting the reader

Nedap cable pigtail

CAT5 cable > Orion PRT 1 or 2

Signal

Nedap cable pigtail

CAT5 cable > Orion PRT 1 or 2

Signal

Brown

Orange&Green

RS485 A

Green

White/Orange & White/Green

RS485 B

Black

Brown

0VDC

Red

External Power supply

12-24VDC

5. Implementation

5.1 General

OSDP readers are completely handled by the nodemanager, so the nodemanager should run to obtain access by a OSDP card reader.

5.2.1 Configure the reader in iProtect

Follow the steps below to configure an OSDP reader:

  1. Connect the reader (see chapter “Connecting the reader”)

  2. Press the discover button in the line dialog of the Pluto.

  3. Wait until the discover process is ready: Read-in event=> Read-in event: Stop, Line: xxx…

  4. Refresh the line dialog of the Pluto, if an OSDP device is detected it will be shown as a Node below the Port of the Orion where the reader is connected to.

  5. Change the OSDP compatibility setting at the OSDP node to “No reader in capabilities”

  6. Right mouse click at the OSDP reader in the treeview and click on “add reader”

    • Fill in the logic unique name of the reader.

    • Click on the save button.

5.2.2 NVITE OSDP defaults

OSDP address

0

Communication speed

9600 baud

Port setting

N81

5.3 OSDP reader settings

For OSDP readers there are some specific settings.

It’s possible to setup the buzzer time when a card is recognized, this can be done at the door behavior tab of the reader.

Buzzer time | card recognized

Buzzer time | card recognized

Setting

Behavior

Empty

No buzzer when card is recognized

1 - 15

buzzer time (1/10 sec)

6. Secure channel

OSDP v2 with Secure Channel has AES-128 encryption to ensure that communication between the targeted devices is strict and secure.

All OSDP devices have a known standard Secure Channel Base Key (SCBK), according to the OSDP specification. The SCBK is a key shared between the peripheral/reader and the controller, which is used once to initiate encryption. The SCBK allows the controller (Pluto/ApolloN) to send a challenge command (critical information that the peripheral/reader can use to initiate a Secure Channel session). Note that OSDP security is not limited to the Secure Channel Base Key. The SCBK is used only once at the start of the session before auto-generated session keys are used to encrypt the OSDP data.

If the security status is “Active scbkd” at the node you can set a random key with the button <Set keys (SC)>. If pressed the key is set into the reader and stored in the controller (Pluto / ApolloN)
Refresh the page to see the results.

7. Settings card coding

7.1 NVITE DESFire

This below cardata interpretation can be linked to the existing DESFire card number presentation.

In iProtect browse to the menu Access → Settings → Card coding → Card data interpretation. Right mouse click in the treeview dialogue and click Add card data interpretation.

Enter the following data:

Name:

OSDP NVITE DESfire

Card number presentation:

Select the existing DESFire presentation

Format:

 

Reader communication protocol:

ABA

Card type:

None

Data Length:

16

System code:

 

Start:

5

Code:

002974 (for demo cards)

Facility:

 

Start:

1

Code:

0600

Card number:

 

Start

11

Length:

6

Modulo:

 

Offset:

 

Interpretation selection

 

Start:

1

Length:

0

Code:

 

Expire date:

 

Start

1

Length:

0

Date control:

No expire date check

Format:

YYMMDD

Keypad

Do not change

Offline Validity:

Do not change

SV WO:

Do not change

Consistency:

Do not change

7.2 NVITE Crypted QR

The card data interpretation below can be linked to a standard QR code presentation, which can be generated using the card number presentation wizard.

In iProtect, navigate to the menu Access → Settings → Card coding → Card number presentation.

Right-click in the treeview dialog and select 'Wizard card number presentation.'

Enter a logical name and choose the QR code option from the default card data interpretation list.

Click the OK button.

After refreshing the page, you will see a new card number presentation and a corresponding card data interpretation. Modify the card data interpretation settings as follows:

Name:

OSDP NVITE QR crypted

Format:

 

Reader communication protocol:

Hexadecimal

Card type:

QR barcode

Encryption:

Aes128

Encryption key:

your key

Data Length:

32

System code:

 

Start:

1

Length:

6

Code:

000b9e (for demo cards)

Facility:

 

Start:

1

Length:

11

Code:

00000000000

Card number:

 

Start

7

Length:

6

Modulo:

 

Offset:

 

Interpretation selection

 

Start:

0

Length:

0

Code:

 

Expire date:

 

Start

13

Length:

8

Date control:

Expire date check, including date

Format:

YYYYMMDD

Keypad

Do not change

Offline Validity:

Do not change

SV WO:

Do not change

Conssistancy:

Do not change

Filter:

 

Start tag:

0300

End tag:

 

 

 