Note |
---|
Once a key is set into the reader it cannot be cleared or rewritten by the system (not allowed in the OSDP protocol, security risk). If the key must be cleared (Reset) follow the procedure what is delivered by the reader manufacturer. |
7. Settings card
...
coding
7.1 NVITE DESFire
This below cardata interpretation can be linked to the existing DESFire card number presentation.
In iProtect browse to the menu Access → Settings → Card coding → Card data interpretation. Right mouse click in the treeview dialogue and click Add card data interpretation.
Enter the following data:
Name: | OSDP NVITE DESfire |
Card number presentation: | Select the existing DESFire presentation |
Format: |
|
Reader communication protocol: | ABA |
Card type: | None |
Data Length: | 16 |
System code: |
|
Start: | 5 |
Code: | 002974 (for demo cards) |
...
Consistency: | Do not change |
7.2 NVITE Crypted QR
The card data interpretation below can be linked to a standard QR code presentation, which can be generated using the card number presentation wizard.
In iProtect, navigate to the menu Access → Settings → Card coding → Card number presentation.
Right-click in the treeview dialog and select 'Wizard card number presentation.'
Enter a logical name and choose the QR code option from the default card data interpretation list.
Click the OK button.
After refreshing the page, you will see a new card number presentation and a corresponding card data interpretation. Modify the card data interpretation settings as follows:
Name: | OSDP NVITE QR crypted |
Format: |
|
Reader communication protocol: | Hexadecimal |
Card type: | QR barcode |
Encryption: | Aes128 |
Encryption key: | your key |
Data Length: | 32 |
...