This document assumes standard T-568-B color coding of the cables.
Pin number RJ-45 Plug | Cable color | Signal ID | T568B Pair | |
1 | White/orange | DA+ | 2 | |
2 | Orange | DA- | 2 | |
3 | White/green | DB+ | 3 | |
4 | Blue | DC+ | 1 | |
5 | White/blue | DC- | 1 | |
6 | Green | DB+ | 3 | |
7 | White/brown | DD+ | 4 | |
8 | Brown | DD- | 4 |
1.2 Tools and equipment
When installing the Sirius iX30, the following tools or materials may be needed.
...
The following accessories are available for the Sirius iX30-IK
Mounting components | Part number |
Mounting screw stainless steel 4,8 x 38 mm | 801-5410 |
Plug Fisher Duopower S6 x 40 mm | 801-5411 |
2. Installation
To ensure proper functioning of the equipment, the environment of the Sirius iX30-IK must be compliant with certain conditions.
...
The configuration defines which card type is read by default by the Sirius iX30-IK.
Functionality | 801-5301 TKH coded | 801-5302 CSN | 801-5303 Programmable |
Standard communication | RS485 & Clock/Data | RS485 & Clock/Data | - |
Read CSN | No | Yes | - |
Read coded TKH cards | Yes | No | - |
Output length | 8 or 12 digits | 10 or 17 digits | - |
Reads programable cards | No | No | Yes |
Tamper output | Yes | Yes | - |
Buzzer input | Yes | Yes | - |
LED input | Yes | Yes | - |
Default LED settings | Red/Green | Red/Green | Blue |
3.1.1 801-5401 TKH Coded
The Sirius iX30-IK TKH coded can both read TKH coded Mifare classic cards and TKH coded Mifare DESFire cards simultaneously and works by default at the following devices.
Protocol | Hardware device (door controller) |
RS485 | Orion (stacked) |
RS485 | Polyx |
Clock/Data | Orion (KpBus) |
Clock/Data | Orbit |
Clock/Data | Third party devices* |
*since clock/data is an standard, the Sirius iX30-IK should work by default on third party controllers which supports the clock/data communication protocol. We strongly recommend to test it on forehand.
...
The Sirius iX30-IK reads both 4 byte and 7 byte CSN simultaneously and works by default at the following devices:
Protocol | Hardware device (door controller) |
RS485 | Orion (stacked) |
RS485 | Polyx |
Clock/Data | Orion (KpBus) |
Clock/Data | Orbit* |
Clock/Data | Third party devices** |
* 7byte CSN cannot be processed by the Orbit!
...
The Sirius iX30-IK 801-5303 programmable does not contain any configuration by default. Programming the Sirius iX30-IK depends on the connection/protocol.
Protocol | Hardware device (door controller) | How to program |
RS485 | Orion (stacked) | Reader configuration file |
RS485 | Polyx | Reader configuration file |
Clock/Data | Orion (KpBus) | Configuration card |
Clock/Data | Orbit* | Configuration card |
Clock/Data | Third party devices** | Configuration card |
Reader configuration file:
...
The following interfaces are by default available on the Sirius iX30-IK.
...
Label | Interface | Description |
A | Light guide | Multicolor RGB LED to display current status |
B | Buzzer | Multitone buzzer for audio feedback |
C | DIP switch | 3-pins DIP switch for RS485 purpose |
D | 9-Pins connector | Connector to connect card reader to door controller |
E | Tamper | Tamper to monitor sabotage |
3.4 Connections
...
Pin | description |
5-16VDC | Power connection (5-16 Vdc) * |
GND | Ground |
A | RS485 A |
B | RS485 B |
LED | Activate LED input |
BUZ | Activate Buzzer input |
TAMP | Tamper contact |
D0 | Clock/data- Wiegand, open collector |
D1 | Clock/data- Wiegand, open collector |
* The Sirius iX30-IK accepts a power between 5.0 and 16.0 Vdc. A higher input voltage results in lower power consumption and ensuring cost-efficient wiring with a smaller conductor diameter. When using an external power supply, it must comply with SELV guidelines.
Advised to power the reader with a power supply that can supply a minimum of 5W to a maximum of 15W. If the reader is powered by a power supply with a power higher than 15W, a fuse of 500mA must be placed by the installer.
DIP SWITCH
Function | 1 | 2 | 3 | DIP-switch 3: |
DEFAULT | Off | Off | On | |
Polyx | On | On | Off | |
Ext. | Off | Off | Off |
3.4.1 RS485 directly
Recommended cable type between the Orion or Polyx and the Sirius iX30-IK card reader is:
...
If any of the above conditions applies, see chapter 4.4.2.
Pin number RJ-45 Plug | Cable color | Signal | T568B Pair | |
1 | White/orange | B | B | |
2 | Orange | A | A | |
3 | White/green | B | B | |
4 | Blue | VCC | 5-16VDC | |
5 | White/blue | - | - | |
6 | Green | A | A | |
7 | White/brown | - | - | |
8 | Brown | GND | GND |
...
3.4.2 RS485 via Adapter board
...
Adapter board is connected with the door controller with a default UTP cat5 cable (or higher) (plug connection).
Or screw connection on adapter board | Or RJ45 connection on adapter board | Cable color | Signal | Sirius iX30-IK |
A (or1) | 1 | White/orange | B | B |
B (or 2) | 2 | Orange | A | A |
Y (or 3) | 3 | White/green | B | B |
+ | 4 | Blue | VCC | 5-16VDC |
| 5 | White/blue |
|
|
Z (or6) | 6 | Green | A | A |
| 7 | White/brown |
|
|
- | 8 | Brown | GND | GND |
Connect GND of the Adapter board to the local earth.
Connect the shield of the ground cable to the GND connection of the Adapter board.
...
CKY 3x2x0,14mm²
CKY 4x2x0,14mm²
CAT5 UTP four twisted pairs of 24AWG copper conductors
CAT6 UTP four twisted pairs of 24AWG copper conductors
Cable color | Connection door controller | Sirius iX30-IK |
White/orange | Data/D0 | D0 |
Orange | TAMP | TAMP |
White/green | Clock/D1 | D1 |
Blue | VCC (+) | 5-16VDC |
White/blue | LED | LED |
Green | BUZZ | BUZZ |
White/brown | GND | GND |
Brown | GND | GND |
Cable color | Connection door controller | Sirius iX30-IK |
Green | Data/D0 | D0 |
Yellow | Clock/D1 | D1 |
Pink | VCC (+) | 5-16VDC |
Grey | LED | LED |
White | GND | GND |
Brown | GND | GND |
3.4.4 Cable lengths if connected directly to Orion
Cable | Communication protocol | Cable length(m) | Communication between | |
UTP ≥Cat5e | RS485 Powered from Orion | 120 |
Orion and Sirius iX30-IK card reader | |
RS485 External powered | 600 | |||
Wiegand | 120 | |||
Clock/Data | 50 |
3.4.5 Cable lengths generic
Cable | Communication protocol | Cable length (m) | Communication between |
| RS485* | 600 |
Controller and Sirius iX30-IK card reader |
Wiegand | 120 | ||
Clock/Data | 50 |
* Please be sure that the cable used for RS485, is suitable for the RS485 protocol.
...
4. Technical specifications
| ||
Power |
Supply voltage | 5- 16VDC (max: 1,4W) |
Measure |
Housing | 145 x 82 x 24 mm |
PCB | 116 x 38 mm |
Environment | IP rating |
IP55 |
Operating temp. | -35 … 60ºC |
Storage temp. | -40 … 85ºC |
Interface |
Header | 9-pins plug connector, small pitch (3.5 / 3.81 mm) |
Simplex | Wiegand, open collector | |
Clock data, open collector | ||
RS485 |
| |
Frequencies | 13,56MHz | Card detection |
2,4GHz band | Wireless connection | |
Cards | Standard | ISO 14443-A |
Type | Mifare Classic, Mifare DESFire 0.6, EV1 and EV2 | |
Distance | 20-70mm (normal operation) | |
Main header inputs | LED | With internal pull-up (switch to GND) (3.3V, <1mA, over voltage protected) |
Buzzer | ||
Main header output | Tamper | Open collector without pull-up |
Clock/data- Wiegand | ||
User interface | Optic | RGB led / Light guide |
Sound | Multi tone buzzer, 85dB at 1 meter | |
Certification | Electric | EMC / LVD / CE |
Radio | R&TTE |