Installation Manual | IM-

20220714

20231122-MB-01

Access Control | Readers | Sirius Card Readers |

view-file

nameIM-20220714-MB-01.pdf

Table of Contents

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

...

This document assumes standard T-568-B color coding of the cables.

Image Modified

Pin number RJ-45 Plug

TIA/EIA-568-B

Cable color

Signal ID

T568B Pair

1

White/orange

DA+

2

2

Orange

DA-

2

3

White/green

DB+

3

4

Blue

DC+

1

5

White/blue

DC-

1

6

Green

DB+

3

7

White/brown

DD+

4

8

Brown

DD-

4

1.2 Tools and equipment

When installing the Sirius iX30, the following tools or materials may be needed.

...

The following accessories are available for the Sirius iX30-IK

Mounting components

Part number

Mounting screw stainless steel 4,8 x 38 mm

801-5410

Plug Fisher Duopower S6 x 40 mm

801-5411

2. Installation

To ensure proper functioning of the equipment, the environment of the Sirius iX30-IK must be compliant with certain conditions.

...

The configuration defines which card type is read by default by the Sirius iX30-IK.

Functionality

801-5301 TKH coded

801-5302 CSN

801-5303 Programmable

Standard communication

RS485 & Clock/Data

RS485 & Clock/Data

-

Read CSN

No

Yes

-

Read coded TKH cards

Yes

No

-

Output length

8 or 12 digits

10 or 17 digits

-

Reads programable cards

No

No

Yes

Tamper output

Yes

Yes

-

Buzzer input

Yes

Yes

-

LED input

Yes

Yes

-

Default LED settings

Red/Green

Red/Green

Blue

3.1.1 801-5401 TKH Coded

 The Sirius iX30-IK TKH coded can both read TKH coded Mifare classic cards and TKH coded Mifare DESFire cards simultaneously and works by default at the following devices.

Protocol

Hardware device (door controller)

RS485

Orion (stacked)

RS485

Polyx

Clock/Data

Orion (KpBus)

Clock/Data

Orbit

Clock/Data

Third party devices*

*since clock/data is an standard, the Sirius iX30-IK should work by default on third party controllers which supports the clock/data communication protocol. We strongly recommend to test it on forehand.

...

The Sirius iX30-IK reads both 4 byte and 7 byte CSN simultaneously and works by default at the following devices:

Protocol

Hardware device (door controller)

RS485

Orion (stacked)

RS485

Polyx

Clock/Data

Orion (KpBus)

Clock/Data

Orbit*

Clock/Data

Third party devices**

* 7byte CSN cannot be processed by the Orbit!

...

The Sirius iX30-IK 801-5303 programmable does not contain any configuration by default. Programming the Sirius iX30-IK depends on the connection/protocol.

Protocol

Hardware device (door controller)

How to program

RS485

Orion (stacked)

Reader configuration file

RS485

Polyx

Reader configuration file

Clock/Data

Orion (KpBus)

Configuration card

Clock/Data

Orbit*

Configuration card

Clock/Data

Third party devices**

Configuration card

 Reader configuration file:

...

The following interfaces are by default available on the Sirius iX30-IK.

...

Label

Interface

Description

A

Light guide

Multicolor RGB LED to display current status

B

Buzzer

Multitone buzzer for audio feedback

C

DIP switch

3-pins DIP switch for RS485 purpose

D

9-Pins connector

Connector to connect card reader to door controller

E

Tamper

Tamper to monitor sabotage

3.4 Connections

...

Pin

description

5-16VDC

Power connection (5-16 Vdc) *

GND

Ground

A

RS485 A

B

RS485 B

LED

Activate LED input

BUZ

Activate Buzzer input

TAMP

Tamper contact

D0

Clock/data- Wiegand, open collector

D1

Clock/data- Wiegand, open collector

* The Sirius iX30-IK accepts a power between 5.0 and 16.0 Vdc. A higher input voltage results in lower power consumption and ensuring cost-efficient wiring with a smaller conductor diameter. When using an external power supply, it must comply with SELV guidelines.

 Advised to power the reader with a power supply that can supply a minimum of 5W to a maximum of 15W. If the reader is powered by a power supply with a power higher than 15W, a fuse of 500mA must be placed by the installer.

DIP SWITCH

Function

1

2

3

Image Modified

DIP-switch 3:
RS485 terminator

DEFAULT

Off

Off

On

Polyx

On

On

Off

Ext.

Off

Off

Off

 3.4.1 RS485 directly

Recommended cable type between the Orion or Polyx and the Sirius iX30-IK card reader is:

...

 If any of the above conditions applies, see chapter 4.4.2.

Image Modified

Pin number RJ-45 Plug

TIA/EIA-568-B

Cable color

Signal

T568B Pair

1

White/orange

B

B

2

Orange

A

A

3

White/green

B

B

4

Blue

VCC

5-16VDC

5

White/blue

-

-

6

Green

A

A

7

White/brown

-

-

8

Brown

GND

GND

...

3.4.2 RS485 via Adapter board

...

 Adapter board is connected with the door controller with a default UTP cat5 cable (or higher) (plug connection).

Or screw connection on adapter board

Or RJ45 connection on adapter board

TIA/EIA-568-B

Cable color

Signal

Sirius iX30-IK

A (or1)

1

White/orange

B

B

B (or 2)

2

Orange

A

A

Y (or 3)

3

White/green

B

B

+

4

Blue

VCC

5-16VDC

 

5

White/blue

 

 

Z (or6)

6

Green

A

A

 

7

White/brown

 

 

-

8

Brown

GND

GND

  • Connect GND of the Adapter board to the local earth.

  • Connect the shield of the ground cable to the GND connection of the Adapter board.

...

  • CKY 3x2x0,14mm²

  • CKY 4x2x0,14mm²

  • CAT5 UTP four twisted pairs of 24AWG copper conductors

  • CAT6 UTP four twisted pairs of 24AWG copper conductors

TIA/EIA-568-B

Cable color

Connection door controller

Sirius iX30-IK

White/orange

Data/D0

D0

Orange

TAMP

TAMP

White/green

Clock/D1        

D1

Blue

VCC (+)

5-16VDC

White/blue

LED

LED

Green

BUZZ

BUZZ

White/brown

GND

GND

Brown

GND

GND

Cable color

Connection door controller

Sirius iX30-IK

Green

Data/D0

D0

Yellow

Clock/D1

D1

Pink

VCC (+)

5-16VDC

Grey

LED

LED

White

GND

GND

Brown

GND

GND

3.4.4 Cable lengths if connected directly to Orion

Cable

Communication protocol

Cable length(m)

Communication between

 

UTP ≥Cat5e   

RS485 Powered from Orion

120

 

Orion and Sirius iX30-IK card reader

RS485 External powered

600

Wiegand

120

Clock/Data

50

3.4.5 Cable lengths generic

Cable

Communication protocol

Cable length (m)

Communication between

 

 

RS485*

600

 

Controller and Sirius iX30-IK card reader

Wiegand

120

Clock/Data

50

* Please be sure that the cable used for RS485, is suitable for the RS485 protocol.

...

4. Technical specifications

 

Power

supply

Supply voltage

5- 16VDC (max: 1,4W)

Measure

housing

Housing

145 x 82 x 24 mm

PCB

116 x 38 mm

Environment

IP rating

IP66

IP55

operating

Operating temp.

-35 … 60ºC

storage

Storage temp.

-40 … 85ºC

interface

Interface

header

Header

9-pins plug connector, small pitch (3.5 / 3.81 mm)

simplex

Simplex
(read only)

Wiegand, open collector

Clock data, open collector

RS485

  • Half duplex, support speeds up to 250Kbps

  • ±2/4/8kV protection airgap discharge

  • ±6 kV contact discharge,

  • ±8 kV using the Human Body Model.

  • Compatible with RS485 standard, Polyx, Orion and Apollo. (Configuration with DIP switches).

Frequencies

13,56MHz

Card detection

2,4GHz band

Wireless connection

Cards

Standard

ISO 14443-A

type

Type

Mifare Classic, Mifare DESFire 0.6, EV1 and EV2

Distance

20-70mm (normal operation)

Main header inputs

LED

With internal pull-up (switch to GND)

(3.3V, <1mA, over voltage protected)

Buzzer

Main header output

Tamper

Open collector without pull-up
(max 500 mA, over voltage protected (Vcc))

Clock/data- Wiegand

User interface

Optic

RGB led / Light guide

sound

Sound

Multi tone buzzer, 85dB at 1 meter

Certification

Electric

EMC / LVD / CE

Radio

R&TTE