Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

How To Article | HTA-20230206-LG-01

iProtect Access / Security | How To Articles |

Image Added

View file
nameHTA-20230206-LG-01.pdf

Table of Contents

How to update the iProtect™ Application.

Ask our service and support desk for the latest ServicePack and iProtect™ version, it is also important that the OS (iPuntu) is up to date as wellDownload the latest files on our download section of the knowledgebase:

https://tkhsecurity.atlassian.net/wiki/spaces/KB/pages/9171081916/iProtect+-+Software+Downloads#Version-10.1-and-lower%3A

Note

Do NOT use the files for version 10.2 on 10.1 or older systems. This will damage your system.

Prechecks

Before the update it is required that the state of the system is known. Not functioning readers, nodes and lines must be noted.

Compatibility and discontinued hardware/software is noted in the release notes:

https://tkhsecurity.atlassian.net/l/cp/Co1YADGz

Tested versions:

  • Firmware inbraak (Unii 2.4.0 / ML 5.0.5 / XL 3.11)

  • Rootfs Pluto's (5.68a)

  • Firmware polyx (UBIFS)

  • Diva/Sense (2.5)

Update

  • Be sure that no users are logged in making changes (new passes etc.).

  • Set all lines inactive.

  • Disable connected third party applications (API-couplings).

  • Download the Backup from the maintenance page. If needed, make a fresh backup first if there are changes made in iProtect.

Upload the new iProtect™ version at the maintenance page

...

You must delete browser history before logging in to iProtect.

Installing the new license if iProtect version was < 10.1:

https://tkhsecurity.atlassian.net/l/cp/51UgXjhX

If a new license is needed, please contact our orderdesk.

Activating lines

To be sure all lines and nodes gets the latest software, select the system default Provisioner group.

...

Activate the line’s now, the Door controllers will get the new software and start with the installation automatically. The doors will be non-functional for 5-10 minutes. Open doors beforehand if they are critical.

Finishing the update

When all lines are updated and the re-index message is gone, you can finish the update with the button in the menu:

Installation > Database restore > Activate line

Some points to check:

  • Readers

  • Database couplings

  • Client login (remove browser cache)

  • Import / Export

  • iNVR

  • Printing badges/cards

  • Intercom

  • browser certificate