Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Installation

manual iX-30IK
  • Product

  • Installation

  • Connection

  • Technical data

    Manual | IM-20231122-MB-01

    Access Control | Readers | Sirius Card Readers |

    View file
    nameKB-_Sirius iX30-IK-230124-073517.pdf

    Table of Contents

    This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

    Table of content

    Table of Contents
    minLevel1
    maxLevel2
    outlinetrue
    indent-
    typeflat

    1. General

    ...

    1. General

    The Sirius iX30 IK10 classified IP66 card reader is a versatile card reader which support multiple card technologies and communication protocols used in access control solutions. In addition, the Sirius iX30-IK is able to support different technologies simultaneously.

    ...

    This document assumes standard T-568-B color coding of the cables.

    Image Modified

    Pin number RJ-45 Plug

    TIA/EIA-568-B

    Cable color

    Signal ID

    T568B Pair

    1

    White/orange

    DA+

    2

    2

    Orange

    DA-

    2

    3

    White/green

    DB+

    3

    4

    Blue

    DC+

    1

    5

    White/blue

    DC-

    1

    6

    Green

    DB+

    3

    7

    White/brown

    DD+

    4

    8

    Brown

    DD-

    4

    1.2 Tools and equipment

    When installing the Sirius iX30, the following tools or materials may be needed.

    ...

    The following accessories are available for the Sirius iX30-IK

    Mounting components

    Part number

    Mounting screw stainless steel 4,8 x 38 mm

    801-5410

    Plug Fisher Duopower S6 x 40 mm

    801-5411

    2. Installation

    To ensure proper functioning of the equipment, the environment of the Sirius iX30-IK must be compliant with certain conditions.

    ...

    The configuration defines which card type is read by default by the Sirius IPR-iX30-IKiK10.

    Standard communication

    RS485 & Clock/Data

    RS485 & Clock/Data

    -

    Read CSN

    No

    Yes

    -

    Read coded TKH cards

    Yes

    No

    Functionality

    801-5301 TKH coded

    801-5302 CSN

    801-5303 Programmable

    IPR-iX30-iK10-MDF

    IPR-iX30-iK10-UID

    IPR-iX30-iK10-PRM

    Communication

    RS485

    RS485

    RS485

    Cosmos Access support

    yes

    yes

    yes

    Card data output

    Clock/data

    Clock/data

    -

    Output length

    8 or 12 digits

    10 or 17 digits

    -

    Reads programable

    Read coded TKH cards

    No

    Yes

    No

    Yes

    -

    Read CSN

    No

    Yes

    -

    Reads Configuration cards

    No

    No

    Yes

    Tamper output

    Yes

    Yes

    -

    Buzzer input

    Yes

    Yes

    -

    LED input

    Yes

    Yes

    -

    Default LED

    settings

    color

    Red/Green

    Red/Green

    Blue

    3.1.1

    ...

    IPR-iX30-iK10-MDF

    The Sirius iX10 IPR-iX10-MDF can read both TKH coded MIFARE Classic cards and TKH coded Mifare MIFARE DESFire cards simultaneously and works by default at the following devices.

    ...

    Protocol

    ...

    Hardware device (door controller)

    ...

    RS485

    ...

    Orion (stacked)

    ...

    RS485

    ...

    Polyx

    ...

    Clock/Data

    ...

    Orion (KpBus)

    ...

    Clock/Data

    ...

    Orbit

    ...

    Clock/Data

    ...

    Third party devices*

    *since clock/data is an standard, the Sirius iX30-IK should work by default on third party controllers which supports the clock/data communication protocol. We strongly recommend to test it on forehand.

    3.1.1.1 Output differs per card type

     

    TKH Security Mifare Classic:

    • 4 digits system code     e.g.: 1234

    • 4 digits card number     e.g.: 6789

    Result as output: 12346789

      

    TKH Security Mifare DESFire:

    • 6 digits system code     e.g.: 123456

    • 6 digits card number     e.g.: 789012

    Result as output: 123456789012

    3.1.2 801-5402 CSN

    The Sirius iX30-IK reads both 4 byte and 7 byte CSN simultaneously and works by default at the following devices:

    ...

    Protocol

    ...

    Hardware device (door controller)

    ...

    RS485

    ...

    Orion (stacked)

    ...

    RS485

    ...

    Polyx

    ...

    Clock/Data

    ...

    Orion (KpBus)

    ...

    Clock/Data

    ...

    Orbit*

    ...

    Clock/Data

    ...

    Third party devices**

    * 7byte CSN cannot be processed by the Orbit!

    ** since clock/data is an standard, the Sirius iX30-IK should work by default on third party controllers which supports the clock/data communication protocol. We strongly recommend to test it on forehand.

    3.1.2.1 Output differs per card type

     

    4Byte CSN:

    • 10 digits CSN

    Result as output: 1234567890

     

    7Byte CSN:

    • 17 digits CSN  

    Result as output: 12345678901234567

    3.1.3 801-5403 Programmable

    The Sirius iX30-IK 801-5303 programmable does not contain . The table below shows an example of the reader output format.

    Example

    MIFARE Classic output

    MIFARE DESFire output

    System code

    4 digits: 1234

    6 digits: 123456

    Card number

    4 digits: 6789

    6 digits: 789012

    Result

    12346789

    123456789012

    3.1.2 IPR-iX30-iK10-UID

    The Sirius IPR-iX30-iK10 reads both 4-byte and 7-byte CSN simultaneously. The table below shows an example of the reader output format.

    Example

    4Byte UID output

    7Byte UID output

    UID

    10 digits

    17 digits

    Result

    123467890

    123456789012

    3.1.3 IPR-iX30-iK10-PRM

    The Sirius iX10 IPR-iX30-iK10 does not have any configuration by default. Programming the Sirius IPR-iX30-IK iK10 depends on the connectioninterface.

    Interface / protocol

    ...

    Protocol

    ...

    Hardware device (door controller)

    ...

    How to program

    ...

    RS485

    ...

    Orion (stacked)

    ...

    Reader configuration file

    ...

    RS485

    ...

    Polyx

    ...

    Reader configuration file

    ...

    Clock/Data

    ...

    Orion (KpBus)

    ...

    Configuration card

    ...

    Clock/Data

    ...

    Orbit*

    ...

    Configuration card

    ...

    Clock/Data

    ...

    Third party devices**

    ...

    Configuration card

     Reader configuration file:

    A by the Hardware Controll Applet generated reader file which determines the exact configuration. This can be distributed central through iProtect.

    • Create reader configuration file.

    • Upload the file per line.

    Detailed information can be found in the manual: TKH Security_HardwareControllApplet.

     

    Configuration card:

    ...

    How to program

    RS485

    Reader configuration file

    Clock/data

    TKH Security configuration card

    3.1.3.1 Configuration card

    If the reader is not used with RS485, a configuration card can be used to program the reader to the customer needs. Settings like the default LED color and brightness, Wiegand or Clock/data output and key material can be changed. To program the programmable reader, a customer specific (config) card is needed.
    This configuration card can be ordered at TKH Security via cardconfig@tkhsecurity.com.

    3.1.3.2 Programming procedure

    • Connect the card reader.

    • Switch on the power. The card readers LED turns into BLUE.

    • Present the configuration card and wait until the card reader restarts.

    • The card readers LED turns into RED. The configuration is complete.

    ...

    The following interfaces are by default available on the Sirius iX30-IK.

    ...

    Label

    Interface

    Description

    A

    Light guide

    Multicolor RGB LED to display current status

    B

    Buzzer

    Multitone buzzer for audio feedback

    C

    DIP switch

    3-pins DIP switch for RS485 purpose

    D

    9-Pins connector

    Connector to connect card reader to door controller

    E

    Tamper

    Tamper to monitor sabotage

    3.4 Connections

    ...

    Pin

    description

    5-16VDC

    Power connection (5-16 Vdc) *

    GND

    Ground

    A

    RS485 A

    B

    RS485 B

    LED

    Activate LED input

    BUZ

    Activate Buzzer input

    TAMP

    Tamper contact

    D0

    Clock/data- Wiegand, open collector

    D1

    Clock/data- Wiegand, open collector

    * The Sirius iX30-IK accepts a power between 5.0 and 16.0 Vdc. A higher input voltage results in lower power consumption and ensuring cost-efficient wiring with a smaller conductor diameter. When using an external power supply, it must comply with SELV guidelines.

     Advised to power the reader with a power supply that can supply a minimum of 5W to a maximum of 15W. If the reader is powered by a power supply with a power higher than 15W, a fuse of 500mA must be placed by the installer.

    DIP SWITCH

    Function

    1

    2

    3

    Image Modified

    DIP-switch 3:
    RS485 terminator

    DEFAULT

    Off

    Off

    On

    Polyx

    On

    On

    Off

    Ext.

    Off

    Off

    Off

     3.4.1 RS485 directly

    Recommended cable type between the Orion or Polyx and the Sirius iX30-IK card reader is:

    ...

     If any of the above conditions applies, see chapter 4.4.2.

    Image Modified

    Pin number RJ-45 Plug

    TIA/EIA-568-B

    Cable color

    Signal

    T568B Pair

    1

    White/orange

    B

    B

    2

    Orange

    A

    A

    3

    White/green

    B

    B

    4

    Blue

    VCC

    5-16VDC

    5

    White/blue

    -

    -

    6

    Green

    A

    A

    7

    White/brown

    -

    -

    8

    Brown

    GND

    GND

    ...

    3.4.2 RS485 via Adapter board

    ...

     Adapter board is connected with the door controller with a default UTP cat5 cable (or higher) (plug connection).

    Or screw connection on adapter board

    Or RJ45 connection on adapter board

    TIA/EIA-568-B

    Cable color

    Signal

    Sirius iX30-IK

    A (or1)

    1

    White/orange

    B

    B

    B (or 2)

    2

    Orange

    A

    A

    Y (or 3)

    3

    White/green

    B

    B

    +

    4

    Blue

    VCC

    5-16VDC

     

    5

    White/blue

     

     

    Z (or6)

    6

    Green

    A

    A

     

    7

    White/brown

     

     

    -

    8

    Brown

    GND

    GND

    • Connect GND of the Adapter board to the local earth.

    • Connect the shield of the ground cable to the GND connection of the Adapter board.

    ...

    • CKY 3x2x0,14mm²

    • CKY 4x2x0,14mm²

    • CAT5 UTP four twisted pairs of 24AWG copper conductors

    • CAT6 UTP four twisted pairs of 24AWG copper conductors

    TIA/EIA-568-B

    Cable color

    Connection door controller

    Sirius iX30-IK

    White/orange

    Data/D0

    D0

    Orange

    TAMP

    TAMP

    White/green

    Clock/D1        

    D1

    Blue

    VCC (+)

    5-16VDC

    White/blue

    LED

    LED

    Green

    BUZZ

    BUZZ

    White/brown

    GND

    GND

    Brown

    GND

    GND

    Cable color

    Connection door controller

    Sirius iX30-IK

    Green

    Data/D0

    D0

    Yellow

    Clock/D1

    D1

    Pink

    VCC (+)

    5-16VDC

    Grey

    LED

    LED

    White

    GND

    GND

    Brown

    GND

    GND

    3.4.4 Cable lengths if connected directly to Orion

    Cable

    Communication protocol

    Cable length(m)

    Communication between

     

    UTP ≥Cat5e   

    RS485 Powered from Orion

    120

     

    Orion and Sirius iX30-IK

    card reader

    RS485 External powered

    600

    Wiegand

    120

    Clock/Data

    50

    3.4.5 Cable lengths generic

    Cable

    Communication protocol

    Cable length (m)

    Communication between

     

     

    RS485*

    600

     

    Controller and Sirius iX30-IK card reader

    Wiegand

    120

    Clock/Data

    50

    * Please be sure that the cable used for RS485, is suitable for the RS485 protocol.

     Please take into account that the power supply at the reader must be between 5-16 VDC.

    ...

    4.

    ...

    Data signals

    ...

    ...

    5. Technical specifications

    ...

    Power

    supply

    Supply voltage

    5- 16VDC (max: 1,4W)

    Measure

    housing

    Housing

    145 x 82 x 24 mm

    PCB

    116 x 38 mm

    Environment

    IP rating

    IP66

    operating

    Operating temp.

    -35 … 60ºC

    storage

    Storage temp.

    -40 … 85ºC

    interface

    Interface

    header

    Header

    9-pins plug connector, small pitch (3.5 / 3.81 mm)

    simplex

    Simplex
    (read only)

    Wiegand, open collector

    Clock data, open collector

    RS485

    • Half duplex, support speeds up to 250Kbps

    • ±2/4/8kV protection airgap discharge

    • ±6 kV contact discharge,

    • ±8 kV using the Human Body Model.

    • Compatible with RS485 standard, Polyx, Orion and Apollo. (Configuration with DIP switches).

    Frequencies

    13,56MHz

    Card detection

    2,4GHz band

    Wireless connection

    Cards

    Standard

    ISO 14443-A

    type

    Type

    Mifare Classic, Mifare DESFire 0.6, EV1, EV2 and

    EV2

    EV3

    Distance

    20-70mm (normal operation)

    Main header inputs

    LED

    With internal pull-up (switch to GND)

    (3.3V, <1mA, over voltage protected)

    Buzzer

    Main header output

    Tamper

    Open collector without pull-up
    (max 500 mA, over voltage protected (Vcc))

    Clock/data- Wiegand

    User interface

    Optic

    RGB led / Light guide

    sound

    Sound

    Multi tone buzzer, 85dB at 1 meter

    Part number

    • IPR-iX30-iK10-PRM

    • IPR-iX30-iK10-UID

    • IPR-iX30-iK10-MDF

    Certification

    Electric

    EMC / LVD / CE

    Radio

    R&TTE