IDESCO OSDP V1 & V2 Manual iProtect Access / Security |
Table of contents
Table of Contents |
---|
1. Introduction
This document is the installation and operation manual for IDESCO OSDP readers.
...
Note |
---|
OSDP v2 is supported by IPROTECT Access 10.3 |
2. Connection the reader
The reader is connected to a stacked Orion (USB). For more information, please consult the manuals of:
...
IDESCO cable type 2 (OSDP V2) | CAT5 cable > Orion PTR1 or PTR2 | RJ45 pin nr: |
D- - Yellow & Yellow/Brown | Green/White & Orange/White | 1 & 3 |
D+ - White & White/Yellow | Green & Orange | 2 & 6 |
GND - Black | Brown | 8 |
VCC - Red | Blue | 4 |
Info |
---|
Max. cable distance between Orion and the IDESCO reader = 120 Mtr, without using an external power supply. |
3. IPROTECT Access
OSDP readers are handled by the nodemanager so provisioning of the reader is not necessary.
3.1 Setup an OSDP reader
Select the line to which the osdp reader should be added.
Select the Orion port to which the osdp reader should be added.
Add a node of type OSDP.
Fill in the standard things like, name, etc.
Select OSDP compatibility
Fully compliant
IDESCO (as non compliant)
IDESCO V2 (as non compliant)
Select the desired baud rate
Used speed is: 9600 baud for IDESCO OSDP card readers
Mark <Node on line> as active
Now the Orion port can be used as OSDP communication port.
Select the created node in the tree view. Click on the right mouse button and select <Add reader>
Set up the reader as usual
Go back to the line and press the discover button
The communication will be started
Version information will now be shown for example:
hw:1000, sw:4470b, SNR:eec70f, VendorCode:48 B3 13
Info |
---|
Autodetection of OSDP readers is not available, so first create the OSDP node and the reader before the discover button is used. |
3.2 Settings
For OSDP readers there are some specific settings:
Keypad buttons
Open the menu item:
Access | Settings | Card coding | Card data interpretation and open the tab: Keypad:
...
KEYPAD | IPROTECT |
---|---|
1-9 | 1-9 |
* | key C in iProtect |
# | used for reset pincode (do not use as pincode only key) |
Buzzer time
Open the menu item:
Installation | Hardware | Reader and open the tab: Door behavior:
Buzzer time, card recognized | Meaning |
---|---|
null <Empty> | no buzzer when card is recognized |
0 | not allowed |
1 – 15 | buzzer time (1/10 sec) |
> 15 | not allowed |
3.3 Card encoding
Info |
---|
Only fields with data, or fields that need to be specifically set are named in the table below. |
Add Card number presentation (DESFire)
Browse to the menu: Access | Settings | Card coding | Card number presentation
Field | Content |
Name | Logical name (e.g. IDESCO OSDP) |
Format | Decimal |
Calculated length | 6 |
Add OSDP Card data interpretation (DESFire)
Browse to the menu: Access | Settings | Card coding | Card data interpretation
...