Installation Manual | TM-20231105

iProtect Access / Security | Functionalities |

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

Introduction

This article explains how you can implement the voxio -A-3100-A reader based on OSDP communication and describes the functions and settings.

Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Version

License

Version 10.3.15

iProtect basic license

Sufficient reader license

OSDP

Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.

OSDP was approved as an international standard by the International Electrotechnical Commission in May 2020 and has been published as IEC 60839-11-5.

OSDP V2.2 which is based on the IEC 60839-11-5 standard, was released in December 2020.

Connecting the reader

PHG connector

Signal

CAT5 cable > Orion PRT 1 or 2

Pin 1

Not in use

Pin 2

Not in use

Pin 3

B

White/Orange & White/Green

Pin 4

A

Orange&Green

Pin 5

Not in use

pin 6

GND

Brown

Pin 7

VCC 8-30V DC

Blue

Implementation

General

OSDP readers are completely handled by the nodemanager, so the nodemanager should run to obtain access by a OSDP card reader.

The readermanager is not involved by handling the OSDP protocol

Setup an OSDP reader using auto discovery.

  1. Connect the reader (see chapter “Connecting the reader”)

  1. Press the discover button in the line dialog

  1. Wait until the discover process is ready

a.    Read-in event=> Read-in event: Stop, Line: xxx…

  1. Refresh the line dialog, if an OSDP device is detected it will be shown as a Node below the Port

  1. If the <OSDP compatibility>  

  1. Badge 2 times a card at the reader, now the reader will be added below the OSDP node in iProtect (adding the reader manually is also possible)