*571-1013 temperature and humidity sensor
Installation Manual | IM-20210309-TP-42 Access Control | Controllers | Apollo(N) Network Controllers | |
This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.
1 About this manual
1.1 Positioning of the sensor
The sensing device is partially enclosed and mounted to the PCB, so the time to respond to temperature change will be relatively slow.
The sensor should not be placed in direct sunlight, as the radiant heat will become trapped inside the enclosure and will cause higher readings.
1.2 Casing
The sensor is contained in a plastic box with flanges for convenient mounting.
This enclosure is not weatherproof and must only be used indoor.
The casing has a cutout and a screen. The screen will protect the sensor and keeps foreign materials outside. It is also needed to create an slow airflow inside the sensor housing which is needed to measure the temperature and humidity.
Note! When testing the device, DO NOT USE any flammable objects or liquids (e.g. a lighter |
---|
1.3 Connectors
A shielded RJ-45 connector on either end of the unit allows for a simple connection of the sensor.
The type of cable which must be used between the controller and the sensor is: STP or S/FTP cable.
Note! The 571-1013 temperature and humidity sensor is not Ethernet compatible. |
1.4 Two dimensional bar codes
The temperature and humidity sensor will be provided of two stickers with a unique serialnumber. One sticker ending with a T (temperature) and one with a V (humidity).
1.5 Pin-out
The shields of the two connectors are connected together. The shield connection is not connected to circuit ground or any part of the sensor circuit.
1.5.1 Connection to Apollo
Cable: Straight STP or S/FTP
1.5.2 Connection to Orion
Cable: Straight STP or S/FTP