Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Installation Manual | TM-20230511

iProtect Access / Security | Functionalities | OSDP Survision LPR Camera-camera

This manual represents the knowledge at the above-mentioned time. TKH security works non-stop to improve her products. For the most recent technical information please contact your consultant or dealer.

Table of Contents

1. Introduction

The Micropak 5 Survision LPR-camera is an advanced, standalone license plate recognition (LPR) camera designed to deliver high performance with minimal setup. Built for ease and efficiency, the Micropak 5 Survision camera’s offers trigger-free operation, capturing high-speed vehicle plates up to 155 mph (250 km/h) with exceptional accuracy and speed. Its compact design integrates all necessary LPR functions within the camera itself, eliminating the need for an external server.

Key features include adjustable recognition distances from 5 to 49 feet and real-time monitoring for enhanced security. The device supports both European and American plate formats and provides instant data output on plate position, traffic direction, and more.

Micropak 5 is The Survision camera’s are equipped with infrared or white-light LEDs for optimal visibility, and it’s housed in a durable, weather-resistant aluminum body. Built with embedded AI, it offers flexible data outputs, multiple connection options, and can be easily integrated into iProtect.image-20241105-153654.pngImage Removed.

Info

The camera can be connected to the network, but has no function to be used as an overview camera. The image of the camera will also not be able to be made visible in IPROTECT Access.

image-20241106-125434.pngImage Added

image-20241105-153654.pngImage Added

2. Support and license

Below is an overview of support for both the hardware and the software, including the necessary license:

Support

Version

Hardware

License

Version

number

Minimum version

IPROTECT Access

 

>= 10.4.14

iProtect basic license

Sufficient reader license

Pluto rootFS

 

>= 6.12.x

Orion (USB)

 

>= 1.5.34

OSDP LPR-camera

IPS-ON - online card reader license (44)

2.1 Supported cards (License plates)

  • European and American license plates.

Info

It is recommended to update the firmware once a year.... or when you read in the release notes that an enhancement is of interest to you.

3. What is OSDP

Open Supervised Device Protocol (OSDP) is an access control communications standard developed by the Security Industry Association (SIA) to improve interoperability among access control and security products.

...

OSDP V2.2 which is based on the IEC 60839-11-5 standard, was released in December 2020.

https://en.wikipedia.org/wiki/Security_Industry_Association

Info

OSDP readers are only supported by stacked Orions (RS485 connection)

4. Setup LPR-camera

4.

...

1 Setup wizard of LPR unit

Info

Survision's LPR units have an IP address by default, which is printed in the test sheet provided. This IP address is always 192.168.0.XYZ, where XYZ is the conversion (from hexadecimal to decimal) of the two last characters of the MAC address.

  1. Setup a local netwerk and configure the network properly.

  2. Start a Webbrowser and enter the IP-address of the camera

  3. Follow the instructions of the QUICK START GUIDE of the camera.

4.2 VSSsetup tool

Info

For more information, please consult the MANUAL_VSS.xxx.pdf

  1. INSTALLATION AND UPDATE

    1. Launch the program « VSS7setup-7.X-BuildY.exe » provided by Survision.

    2. Choose « English » as installation language and click on « OK ».image-20241106-113435.pngImage Added

    3. Click on « Next ».

    4. Read the license agreement, click on « I understand and accept …» and click on « Next ».

    5. If needed, change the installation path and click on « Next ».

    6. If needed, modify the path for the shortcuts on Windows « Start » menu and click on « Next ».

    7. Select whether you want to create a shortcut on Windows Desktop and click on « Next ».

    8. Verify the installation options summary and click on « Install ».

    9. Wait for the installation to end.

    10. Click on « Finish »

  1. Start VSS by clicking on any of the shortcuts that the installation has created or just run the application on [path]\Survision\VSS7\VSS7.exe.
    The image below shows the Main View (before connecting to any specific unit).

...

  1. Enter the correct IP addres and press on the button Connect.

  2. Lock the camera to be able to change settings:

...

  1. Open in the main menu View and Settings Window, the following windows will be opened:

...

  1. Select Settings

  2. Edit Camera | ANPR | Serial output

image-20241106-120555.pngImage Added

  1. Change the Mode to OSDP and set an unique Address and press OK.

Info

This Address is needed for IPROTECT.

  1. Close this window

  2. Lock the camera and close this window.

5. Hardware Installation

5.1 Positioning of the LPR camera

The successful positioning of the LPR unit relies on several key factors. To ensure a proper installation, please adhere to the following essential steps and guidelines.

Understanding the importance of the LPR camera's position is crucial, as it must be carefully evaluated alongside the LPR settings. The angle, height, and distance from the target area can greatly affect the camera's ability to accurately capture license plate information.

For example, if the camera is mounted too high or at an inappropriate angle, it may struggle to read plates, particularly those that are angled or obscured. Additionally, the LPR system settings—such as exposure, focus, and frame rate—should be fine-tuned to correspond with the camera's specific positioning to guarantee optimal performance.

Info

For further details, please consult the Survision manual.

...

5.2 Connecting the LPR camera to the Orion

The LPR camera connects directly to the Orion Kp bus connector via a fixed cable, with a maximum distance of 15 meters between the camera and the Orion unit. Additionally, the camera operates using an external 24V power supply.

Cable color

Signal

ABC connector Orion

KpBus (RS485)

Brown

+ 24V

Grey

GND

Green

RS485 A

A

White

RS485 B

B

Yellow

RS GND

CC

Info

Max. cable distance between Orion and the LPR reader -camera= 15 Mtr.

Info

The LPR reader must be connected to an 24V external power supply.

Note

The KpBus connector can only be used when the PRT2 port is not being used.

...

...

6. iProtect Implementation

...

6.1 General

OSDP readers are completely handled by the nodemanager, so the nodemanager should run to obtain access by a OSDP card reader.

The readermanager reader manager is not involved by handling the OSDP protocol.

5.2 Configure the reader in iProtect

...

6.2 Card encoding

To enable license plate recognition, follow these clear steps to create a card configuration within iProtect:

  1. Navigate to Card Configuration:

    • Go to Access > Settings > Card Configuration.

    • Initiate the wizard by right-clicking on the tree view.

  2. Start the Wizard:

    • Click on the button labeled “Wizard card number presentation.”

  3. Configure Presentation:

    • A new pop-up will appear.

    • Enter a logical name for the new presentation, such as “LPR presentation.”

    • Choose for the option: “Number plate no country code”

    • Click the Save button.

6.3 Configure the Reader in iProtect

To configure an OSDP reader, please follow the steps outlined below:

  1. Connect the LPR camera to the Orion (see chapter “Connecting the reader”)refer to chapter 5.2 Connecting the LPR Camera to the Orion).

  2. Press the discover button in the line dialog of the Pluto.

Info

The Address number refers to the specific identifier assigned to the camera, as detailed in chapter 4.2 VSSsetup tool.

  1. Wait

...

  1. for the

...

  1. discovery process

...

  1. to complete: Read-in event => Read-in event: Stop, Line: xxx…

  2. Refresh the line dialog of the Pluto

...

  1. . If an OSDP device is detected, it will

...

  1. appear as a Node below the Prt2 port of the Orion.

  2. Change the OSDP compatibility setting at the OSDP node to

...

  1. “Ascii data as raw data.”

  2. Right

...

  1. -click

...

  1. on the OSDP node in the

...

  1. tree view and select “Add Reader.”

    • Enter a unique logical name for the reader.

...

Click on the save button.

The discover function for OSDP devices checks for the following settings:
Baudrate:                    9600, 19K2, 115K2  baud,  They are all non-parity, 8 bit, 1 stop bit
Device address:          0, 1, 2, 3, 4, 5, 6, 7, 8, 13, 14, 24

If other settings are necessary, set these settings manually.

5.3 OSDP reader settings

For OSDP readers there are some specific settings.

It’s possible to setup the buzzer time when a card is recognized, this can be done at the door behavior tab of the reader.

...

Buzzer time | card recognized

...

Setting

...

Behavior

...

Empty

...

No buzzer when card is recognized

...

1 - 15

...

buzzer time (1/10 sec)

Info

Most used setting for buzzer time = 2

6. Card encoding

...

    • Choose the appropriate card data interpretation in the General tab.

    • Select the output in the Door Control section on the Input/Output tab.

    • Choose the loop input in the Loop selection on the Input/Output tab.

    • (optional) set the read card before loop activation at the door behavior tab.

    • Click the Save button.

Info

The “read card before loop activation” setting can be beneficial when the camera captures the license plate before the vehicle triggers the loop.

7. License Plate Configuration in iProtect

A license plate functions similarly to operates much like a standard card within the iProtect system. To activate enable this feature, you must need to connect the LPR (License Plate Recognition) reader to a reader group, which is then associated with linked to an access profile.

Access is granted to a vehicle when its license plate is linked to associated with a valid access profile that corresponds with to the LPR reader.

For detailed comprehensive instructions on configuring an access profile in iProtect, please refer to this document: *Access rights in iProtect™.

For guidance on how to assign a card (License Plate) to a person record, you can follow this document: https://tkhsecurity.atlassian.net/wiki/spaces/KB/pages/9171076589/Assign+cards+to+people?atl_f=PAGETREE.

8.

...

OSDP v2 with Secure Channel has AES-128 encryption to ensure that communication between the targeted devices is strict and secure.

All OSDP devices have a known standard Secure Channel Base Key (SCBK), according to the OSDP specification. The SCBK is a key shared between the peripheral/reader and the controller, which is used once to initiate encryption. The SCBK allows the controller (Pluto/ApolloN) to send a challenge command (critical information that the peripheral/reader can use to initiate a Secure Channel session). Note that OSDP security is not limited to the Secure Channel Base Key. The SCBK is used only once at the start of the session before auto-generated session keys are used to encrypt the OSDP data.

If the security status is “Active scbkd” at the node you can set a random key with the button <Set keys (SC)>. If pressed the key is set into the reader and stored in the controller (Pluto / ApolloN)
Refresh the page to see the results.

  • The button <Set keys (SC)>  generates and stores a key into the reader

  • The OSDP secure channel key himself is only visible for Root and Installer users

...

Additional information and manuals

8.1 Micropak5

DESCRIPTION

FILE

QUICK START GUIDE

View file
nameMICROPAK5 VARIO QUICK START GUIDE_English.pdf

DATASHEET

View file
namee0afc3_Micropak5EN.pdf

8.2 Nanopak5

DESCRIPTION

FILE

QUICK START GUIDE

View file
nameNANOPAK5 TOTEM QUICK START GUIDE_English.pdf

DATASHEET

View file
name

...

Nanopak 5 Totem English v1.05.pdf