Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

IMPORTANT:

With the release of VDG Sense 2.6.8 some architectural changes are made which break backward compatibility with previous versions of VDG Sense. This also means any SenseClient or SenseServer prior to 2.6.8 is not able to connect to 2.6.8 server.

All settings from 2.6.7 will be migrated automatically during the setup procedures in VDG Sense 2.6.8 setup. To ensure a smooth upgrade it is recommended to upgrade to 2.6.7 prior to upgrading to 2.6.8.

Changes compared to 2.6.7:

  • User Management and Devicegroup tabs have been reworked

  • It is now possible to change user passwords within the application and not via web

  • Faster authentication via API (affects IOS, android, VDG Sense Webpage and third party integrators)

  • Herta and Briefcam integration are temporarily disabled, please contact support for assistance.

  • Reintroduced support for NVH-1003

Note

For Web, API and App access the password of the (migrated) users need to be reconfigured. Follow this procedure for each user:

  1. Open User Management tab

  2. Select user for which web access need to work

  3. Press ‘Change Password’

  4. Change or retype chosen password

  5. After all users are updated goto ‘System’ tab and press ‘Sync Sense’ button

New Features

Improvements

  • VMS-11249 - Reintroduced support for NVH-1003

  • VMS-11186 - Implement PUT, UDPATE and DELETE for webhook [Read More]

  • VMS-11185 - Add extra values to streamEvents event

  • VMS-11174 - PresetError event if PTZ camera does not reach preset position /wiki/spaces/KB/pages/933462383

  • VMS-11144 - Update Nginx to version 1.18

  • VMS-11143 - Update NTP server to version 4.2.8p15

  • VMS-11139 - Update 7Zip to version 21.01

  • VMS-11133 - Framerate configuration in devices tab for TKH Security Solution Driver /wiki/spaces/KB/pages/933101986

  • VMS-11024 - Ability to enable or disable ObjectC via macro

  • VMS-10971 - Digest authentication for webhook action [Read More]

  • VMS-10947 - Search option to add AD users to Sense configuration

  • VMS-10917 - Change bandwidth and resolution for TKH Security Solutions driver /wiki/spaces/KB/pages/933101986

  • VMS-10914 - Record frames per minute [Read More]

  • VMS-10912 - Triple streaming support for TKH Security Solutions driver /wiki/spaces/KB/pages/933101986

Fixes

  • VMS-11312 - Calendar plugin doesn't execute macro

  • VMS-11251 - Server restarts when doing large VCA search queriy

  • VMS-11160 - Videowall issue vs target mode panel

  • VMS-11159 - Onvif driver not able to access camera behind router

  • VMS-11148 - Flashback does not jump back to live

  • VMS-11136 - Vivotek not connecting using native RTSP client

  • VMS-11109 - Webhook is not htmlencoding eventparameters

  • VMS-11104 - Mobotix Mxpeg pdf export not working

  • VMS-11086 - Playback time on timeline changes to real time after switch camera from different server

  • VMS-11052 - Tour starts eventhough camera is deactivated in profile

  • VMS-11048 - Videotag contains no data

  • VMS-11046 - Tour does not start with Timeout action for server based presets

  • VMS-11041 - Unable to access servers that have different admin login

  • VMS-11038 - Sense client VCA crash when switching between devices

  • VMS-11027 - min / max Thermal value is 100 degrees

  • VMS-10996 - Unable to switch to full screen in SensePlayer

  • VMS-10989 - Videopanels zoomed in when using fit to panel after login

  • VMS-10987 - Slow response for PTZ actions for Samsung Wisenet III cameras

  • VMS-10973 - GEO map decimal digits are round-up for the longitude and latitude values

  • VMS-10870 - Export never finishes when missing data in the storage

  • No labels