*Devices – PTZ settings
Configuration Article | CA-20210707-MH-01 VDG Sense | Setup | Devices | PTZ settings |
Configuration
This tab is used to configure PTZ capabilites of cameras supporting PTZ.
Dome type
The PTZ protocol of the connected dome camera.Preset Type
Server Presets: Store Preset position on server.Supported for selected dome drivers
TKH Security Solutions Driver
Pelco
IP Axis
IP Siqura
Device Presets: Store Preset position on device
Dome address
RS-485 address to which the dome is connected to.Baudrate
The configured connection speed. The following options are available: 2400, 4800, 9600, 19200 and 38400.PTZ Timeout
The number of minutes after PTZ movement before the dome is performs the Timeout Action. If set to 0, the timeout action will not occur.Timeout Action
Set the behavior of the PTZ Timeout.Home Preset
Select which preset should act as the “Home preset”Continuous PTZ Polling
Default off, only to be used in API if the position needs to be updated regularly via API events
PTZ polling interval
Works with continuous
Reverse
With the reverse setting the commands for left and right, up and down are reversed.PTZ Control Rose
By dragging the mouse over the control-rose you can control the position of the dome. The zooming factor can be set with the zoom-in and zoom-out buttons. The focus can be set by using the Focus-in and Focus-out or the Auto-Focus button and the Aperture can be set using the Iris-Open and Iris-Close or the Auto-Iris button
Configuring a preset
Defining preset position
Use the PTZ Control-rose to place the device in the desired position
In the Preset list, select the preset number you wish to edit
Click the “Set” button to set the current position as the preset value
Save
Changing Preset name
In the Preset list, select the desired preset
Double click in the name column to edit the name
Type in the preset name
Click outside the list to close the edit dialog
Save
Events
PresetOn, Value=[preserNr]
When server presets are used the PresetOn event is send when the position of the Preset is reached. The presetNr has the value of the preset on which the camera will be set.
When device presets are used the PresetOn event is send when the goto preset command is given. The presetNr has the value of the preset on which the camera will be set.
PresetOff, Value=[preserNr]
The PresetOff event is send when the position is changed or set to a different preset. The presetNr has value of the preset on which the camera was set.
PresetError, Value=[preserNr]
Will be send if server presets are used and the position of a preset is not reached within 30 seconds after the command is given